OWNER`S MANUAL

Tested &

Listed By

Portland

Oregon USA

OMNI-Test Laboratories, Inc,

C

O-T L

US

Report # 268-S-06b-2

Report # 268-S-05-2, 268-S-06c-2

Kodiak 1200 FPI & Kodiak 1700 FPI 

W O O D   S T O V E   I N S E R T

INSTALLER: 

 LEAVE THIS MANUAL WITH THE WOOD STOVE.

 CONSUMER: 

RETAIN THIS MANUAL FOR FUTURE REFERENCE. 

  Version Française: www.enviro.com/fr.html

PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS 

WOOD BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS 

COULD RESULT IN PROPERTY DAMAGE, BODILY HARM, OR EVEN DEATH.

CONTACT YOUR BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND 

INSTALLATION INSPECTION REQUIREMENTS IN YOU AREA.

THIS  HEATER  MEETS  THE  2015  U.  S.  ENVIRONMENTAL  PROTECTION  AGENCY’S  CRIB-

WOOD  EMISSION  LIMITS  FOR  WOOD  HEATERS  SOLD  AFTER  MAY  15,  2015.    UNDER 

SPECIFIC  CONDITIONS  THIS  HEATER  HAS  BEEN  SHOWN  TO  DELIVER  HEAT  AT  RATES 

RANGING FROM 11,479 TO 34,196 BTU PER HOUR FOR THE 1200 AND FROM 9,425 TO 

31,780 BTU PER HOUR FOR THE 1700. THESE STOVES HAVE BEEN CERTIFICATION TESTED 

TO STANDARDS UL-1482-11 AND ULC-S627-00. CERTIFICATION TESTING COMPLETED BY 

OMNI-TEST LABORATORIES.

Summary of Contents for Kodiak 1200 FPI

Page 1: ...WOOD BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY HARM OR EVEN DEATH CONTACT YOUR BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOU AREA THIS HEATER MEETS THE 2015 U S ENVIRONMENTAL PROTECTION AGENCY S CRIB WOOD EMISSION LIMITS FOR WOOD HEATERS SOLD AFTER MAY 15 2015 UNDER SPECIFIC CONDITIONS THIS HEATER...

Page 2: ...0 KI Insert 15 Installation 16 Removal From Pallet 16 Modifications For Installation with 19 483mm High Lintel 16 Masonry Fireplace Installation 17 Installation Using A Block Off Plate For USA Only 20 Model 1200 KI Brick Placement Tube Locations 22 Model 1700 KI Brick Placement Tube Locations 23 C Cast Ceramic Baffle Installation 24 Fan Wiring Diagrams 25 Fan Removal 25 Removal of Top 26 Installat...

Page 3: ...se At least 12 square inches 77 4 cm2 of fresh outside air should be admitted into the room or directly to the stove through a 4 inch 10 16 cm diameter pipe Do not burn wet unseasoned wood this can causes excessive creosote accumulation When this is ignited it can cause a chimney fire that may result in a serious house fire Do not use grates andirons or any other methods to support or raise the fi...

Page 4: ...r has been shown to deliver heat at rates ranging from 9 400 32 000 Btu hr Rates This manual describes the installation and operation of the Enviro Kodiak 1200 wood heater This heater meets the 2015 U S Environmental Protection Agency s wood emission limits for wood emission limits sold after May 15 2015 Under specific test conditions this heater has been shown to deliver heat at rates ranging fro...

Page 5: ...ff When the switch is pushed down it is set to the automatic position 3 In the manual position the Rotary Rheostat knob is used to turn the fan on and off as well as adjust the flow 4 In the automatic position the fan will automatically turn on once the fan temperature sensor reaches the operating temperature When the unit cools down the fan temperature sensor will shut the fan off You should set ...

Page 6: ... your local fire authority will provide you with instructions to handle the situation 4 Once the fire is out examine the flue pipes chimney attic and roof of the house to see if any part has become damaged by the fire 4 Do not operate the stove again until the chimney and its lining have been cleaned and you are certain they have not been damaged We strongly recommend inspection by a WETT Wood Ene...

Page 7: ...s glow red hot Using more than five logs at a time can cause overfiring Keep logs a few inches from the lowest point of the top of the firebox If any logs are touching the tubes in the top of the firebox you can damage the air tubes Overloading the stove can cause damage to the firebox and air tubes and will void the warranty c DO NOT OVERFIRE If the heater or chimney connector glows you are overf...

Page 8: ...ey has started and good combustion is now possible Larger pieces of seasoned dry firewood can now be added when there is sufficient space in the firebox Adjust the air control setting to desired setting Note The lower the air control setting the longer the burn time of your firewood 2 What type of wood is best to use as firewood Both hardwood and softwood burn well in this stove Both woods contain...

Page 9: ... in air starvation to the wood stove This creates a condition in the house known as negative pressure When a house experiences negative pressure the combustion gases can be drawn from the chimney and into the house This condition is commonly referred to as down drafting Increased amounts of insulation vinyl windows extra caulking in various places and door seals can all keep heat in but may also m...

Page 10: ...ot injection ports Slider plate used for air flow control Intake air Seasoned Firewood Exhaust Smoke 1 2 Ceramic baffle reflects heat down to burn the particles in the smoke Secondary air tubes creates a second burn on the particles in the smoke for a more efficient cleaner burn Convection Heat Radiant Heat Primary air window air wash cooler air to keep the glass clean Pilot air through Twin pilot...

Page 11: ...6 mm x 711 mm Oversized width x height 47 5 x 33 1207 mm x 838 mm Rating Label Location Side of Unit Behind Right Shroud Specifications Air Control The amount of combustion air going to the air wash and pilot is controlled by the air control rod located on the right side of the unit To increase your air pull the rod out and to decrease push the rod in All Enviro wood stoves have a secondary air th...

Page 12: ...combustible spacers 14 357 mm Ceramic tiles or equivalent non combustible material on non combustible supports with a minimum of 013 0 33mm sheet metal spaced out 1 25mm by non combustible spacers 10 267 mm NOTES 1 Mantel protection must have at least 3 75mm edge clearance on all sides except as provided in Note 4 2 If an adhesive is used to support non combustible material it shall not lose adhes...

Page 13: ...combustible spacers 16 408 mm Ceramic tiles or eqivalent non combustible material on non combustible supports with a minimum of 013 0 33mm sheet metal spaced out 1 25mm by non combustible spacers 12 305 mm NOTES 1 Mantel protection must have at least 3 75mm edge clearance on all sides except as provided in Note 4 2 If an adhesive is used to support non combustible material it shall not lose adhesi...

Page 14: ...nsions 1200 KI Insert Figure 5 1200 KI Insert Dimensions 28 1 4 715 46 1166 33 1 2 850 20 508 18 1 2 472 22 561 27 687 36 916 13 1 4 336 22 1 2 573 20 1 4 514 19 1 2 493 19 1 2 or 483 19 497 20 3 4 529 5 128 15 3 4 400 14 ...

Page 15: ...Dimensions 1700 KI Insert 28 1 4 715 20 508 18 1 2 472 33 1 2 850 46 1166 20 3 4 526 19 1 2 or 483 19 497 24 3 4 627 24 607 17 3 4 450 27 686 20 1 4 515 5 126 36 916 22 561 27 687 Figure 6 1700 KI Insert Dimensions 15 ...

Page 16: ...19 484mm High Lintel Insert Cabinet Top Air Deflector Figure 10 Removing Air Deflector onto Cabinet Top Figure 9 Removing Cabinet Top from Unit The KI has a factory height of 19 496mm and it can be reduced to 19 483mm by modifying the cabinet top and mounting position Insert Unit 1 Remove the thirteen T 20 screws holding the cabinet top in place refer to Figure 9 2 Remove the cabinet top and flip ...

Page 17: ...ainless steel liner that goes directly to the top of the chimney and is covered with a rain cap The chimney top is sealed with a flashing or steel plate that supports the weight of the chimney liner The installation must conform to the liner s manufacturer s instructions This fireplace must be installed with a continuous liner of 6 diameter CANADA ONLY extending from the fireplace insert to the to...

Page 18: ...ure 13 Insert Installation into existing floor level masonry fireplace Installation Floor Protection Combustible Floor Masonry Fireplace 8 203 mm USA 16 406 mm CND 18 450 mm Figure 12 Insert Installation into existing fireplace without hearth f Place the Collar Puller over the two bolts of the Flue Collar and pull it into place see Figure 14 Ensure that the bolts are to the left and right of the h...

Page 19: ...e Let the silicon or cement dry 2 To make the installation of the surround panel onto the unit easy have the unit 6 150mm out from the fireplace 3 Push the insert into the fireplace allowing the insulation to form a seal between the panels and the fireplace Tuck any exposed insulation behind the face plate Figure 17 Installation with Surround Sealed Masonry Fireplace Mantel Damper Removed or Faste...

Page 20: ...ng Refer to Step 3 NOTE In general masonry fireplaces have square fireboxes while zero clearance metal fireplaces have domed firebox tops Therefore zero clearance block off plates may be more difficult to install Insulation may be used around the edges to simplify sealing the plate 2 Create a cardboard template of the dimensions with 2 51 cm wide flanges on each side These flanges will be used to ...

Page 21: ...eel chimney connector must extend 12 305mm past the block off plate Damper must be removed Zero clearance metal firebox IMPORTANT DO NOT modify any part of the ZC fireplace temperature fiberglass insulation and furnace cement to seal any gaps between the pipe and block off plate allow the cement to dry for at least 24 hours before burning Before starting this type of installation refer to Installa...

Page 22: ...ft until the right end of the tube is freed To installation a secondary air tube reverse the above instructions IMPORTANT All secondary air tubes must be in place for proper operation Partial Brick Full Size Brick Tube A Tube E Tube D Full Size Brick Figure 22 Brick Placement for 1200 KI shown with Secondary Air Channel and Tubes 1 Place the three 3 full size bricks along each side of the firebox ...

Page 23: ...e right end of the tube is freed To installation a secondary air tube reverse the above instructions IMPORTANT All secondary air tubes must be in place for proper operation Full Size Brick Partial Brick Tube A Tube C Tube B Full Size Brick Full Size Brick Figure 23 Brick Placement for 1700 KI shown with Secondary Air Channel and Tubes 1 Place the four 4 full size bricks along each side of the fire...

Page 24: ...e plug DO NOT route the power cord beneath the heater or away from the heat WARNING This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged into a properly grounded three prong receptacle 2 Hook the outside edge of the baffle over the top of the secondary air chamber This will make room to for the installation of the left C Cast C...

Page 25: ... two 8 32 T 20 screws mounting it to the firebox there are two hole in the cabinet side to access screws 2 Disconnect all electrical connections to the fan 3 Remove the four 8 32 X hex head screws that hold the fan mounting plate to the shroud 4 Remove the fan control knob and nut from the front of the shroud and pull the controls out the back 5 Install the fan kit into the new shroud by following...

Page 26: ...Installation of Surround Panel Installation Of The Surround Panel 1 You will need to remove the top as shown above before installing the surround panel 2 Once the top has been removed slide the surround panel over the unit 3 The surround will hook on to the side shrouds 4 Re install the top once the surround is in place 26 ...

Page 27: ...tructions Contact local building or fire officials about restrictions and installation inspection in your area Use 6 150 mm diameter minimum 24 MSG black or 25 MSG blued steel connector listed factory built chimney suitable for use with solid fuels or masonry chimney See local building code and manufacturer s instructions for precautions required for passing a chimney through a combustible wall or...

Page 28: ...Glass Retainer Kit With Screws 50 1122 17 1200 1700 Left Shield Assembly 50 1144 18 1200 1700 Right Shield Assembly 50 1145 19 1200 Ceramic Baffle L R Set 50 1146 20 1700 Ceramic Baffle L R Set 50 1147 21 FPI Flue Collar Assembly 50 1148 22 FPI Angled Flue Collar Assembly 50 1565 23 1200 1700 Ceramic Flue Gasket 50 1413 24 1200 1700 Cast Latch 50 1381 25 1200 1700 Insert Replacement Fan 50 2204 26...

Page 29: ...Parts Diagram 20 31 14 15 17 28 21 23 18 30 33 34 26 27 8 10 11 32 6 16 7 1 2 3 29 4 5 25 22 19 12 13 24 9 35 29 ...

Page 30: ...Notes 30 ...

Page 31: ...g serial number Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from over firing due to incorrect setup or tampering Damage caused by incorrect installation To the Dealer Provide name address and telephone number of purchaser and date of purchase Provide date of purc...

Page 32: ..._____________ _________________________________________ PHONE ___________________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE ______________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy INSTALLER S SIGNATURE _________________________________________ NAME OF INSTALLER _________________________________________ ADDRESS...