background image

50-2257

PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE 

OF THIS PELLET-BURNING ROOM HEATER. FAILURE TO FOLLOW THESE 

INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY 

OR EVEN DEATH.

Contact your building or fire officials about restrictions 

and installation inspection requirements in your area. 



W

AR

RA

NT

Y R

EG

IST

RA

TIO

N

enviro.com/warranty

M55-FPI

P E L L E T   I N S E R T   S T O V E

OWNER’S MANUAL

  Version Française: www.enviro.com/fr.html

The burner system of this pellet stove is designed to actively manage the waste by-products of combustion.  

As a result, you can enjoy the longest cleaning intervals of any pellet insert on the market .  An added advan-

tage that comes with this burner system is that it allows you to burn not just pellets but alternate fuels - corn, 

wheat, barley, grass and bark pellets - without changing any parts!

Summary of Contents for M55-FPIs640

Page 1: ...LD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area W A R R A N T Y R E G I S T R...

Page 2: ...o Locate Your Pellet Appliance 16 Removing Pellet Stove From Pallet 16 Installing the Inset Frame and Levelling 17 Clearances to Combustibles 18 Thermostat Installation 18 Vent Termination Requirement...

Page 3: ...ove needing to be cleaned daily A low ash fuel may allow longer intervals between cleaning CLINKERING clinkers are silica sand or other impurities in the fuel that will form a hard mass during the bur...

Page 4: ...15 2015 Under specific test conditions this heater has been shown to deliver heat at rates ranging from 9 200 45 500 Btu hr Emissions Rating Label Serial No DATE OF MANUFACTURE J F M A M J J A S O N...

Page 5: ...again until you are certain the chimney and its lining have not been damaged OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for prope...

Page 6: ...y suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING A...

Page 7: ...pe Residential Pellet Heater 6mm dia Pellets wood corn wheat barley Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper Capacity Consumption on Low 60 Hz up to 50 lb 22 7 Kg 1 5 lb...

Page 8: ...feed settings When pressed all lights on Heat Level Indicator will come on except the one that is the set point Hold Trim Button down and press the UP or DOWN Heat Level Arrow to adjust setting 3 Lig...

Page 9: ...t operate for the first five minutes after the ON button has been pressed After the ten minutes it will pulse at the same interval as the feed auger When the start up sequence is complete the unit wil...

Page 10: ...water column 37 42 Pa This can be measured using a Magnahelic pressure gauge once the unit has been running on heat level 5 setting after one hour of burn time This adjustment is necessary for varyin...

Page 11: ...o adjust this cover either up or down to control the maximum output of 55 000 BTU Lowering the cover position will decrease output and raising it will increase output CAUTION Increasing output too muc...

Page 12: ...it 3 The agitator locks at the right rotate the top of the agitator towards the back of the firebox to unlock it slide it to the left and lift it out of the burn pot liner 4 Lift the burn pot liner o...

Page 13: ...use the gasketing may come loose To repair this glue the gasketing on using high temperature fiberglass gasket glue available from your local dealer This is important to maintain an airtight assembly...

Page 14: ...N CLEAN UP Once you are finished using the pellet appliance for the season unplug the stove for added electrical protection It is very important that the stove be cleaned and serviced as stated above...

Page 15: ...2 Close up of Front Rail Quick Release Pin Thumb Screw 1 Remove Cast Ash Drawer Front 2 Slide open the Cast Top 3 Lift off Cast Sides 4 Clip Side Rails to unit 5 Attach Front Rail using the quick rele...

Page 16: ...l units installed in Mobile and Air Tight Homes R2000 or where required by local codes 7 Do not obtain combustion air from an attic garage or any unventilated space Combustion air may be obtained from...

Page 17: ...e length of the bolts masonry bricks may be placed under the frame 4 Once level position the Insert Frame in the fireplace cavity so that the Surround Panel is flush with the front of the fireplace 5...

Page 18: ...matically O will drop down t will return to pre and it will restar To Turn Off Stov AUTO OFF mo Pour d marrer qualit de supe carburants App pot de br lure h Pour faire fonct MODE HIGH L tre ajust s L...

Page 19: ...llowable exterior vent termination locations Table 2 Use in conjunction with Figure 6 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass t...

Page 20: ...mes When connecting to an outside fresh air source do not use plastic or combustible pipe A 3 minimum 76 mm ID inside diameter steel aluminum or copper pipe or ducting should be used The inlet must ha...

Page 21: ...Chimneys 6 It is necessary to permanently seal any opening between the masonry of Figure 9 Masonry fireplace installation the fireplace and the facing masonry When installing the insert into a masonry...

Page 22: ...from the fireplace from entering the chimney which will affect proper drafting of appliance Figure 10 Masonry fireplace positive flue installation A qualified installer should evaluate the existing fi...

Page 23: ...st be supported with sheet metal studs and have no combustible material in the air space All venting for Built In installation must use PL or L venting and be installed with vent manufacturer s recomm...

Page 24: ...st caused by airflow around the structure Follow vent manufacturer guidelines for installation clearance to combustibles and sealing of venting High temp Sealant must be used when connecting vent pipe...

Page 25: ...nation Installation Figure 12 Venting horizontally with rise NOTE This venting configuration is only for use with the Built In installation Wall framing Wall thimble Termination cap Vertical section o...

Page 26: ...PL vent upward from the tee Make sure that you install support brackets to keep the vent straight and secure All joints in the exhaust venting system must be fastened with at least three 3 screws 3 I...

Page 27: ...in the exhaust venting system must be fastened with at least three 3 screws 3 Install ceiling thimble and secure the flashing as you go through the roof 4 Ensure that the rain cap is approximately 24...

Page 28: ...If the 3 light is flashing unit may be out of fuel Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT See section 8 The Fuel will not light Check the fuse on the circuit board If the unit still...

Page 29: ...require vertical section to move termination into a low pressure zone To reset Circuit Board after a trouble code push the ON OFF button 5 Unit is on but auger motor does not turn at all Check the li...

Page 30: ...of the Heat Level button make sure the thermostat is calling for heat Call your local dealer for service 10 The stove keeps going out If the stove goes out and leaves fresh unburned fuel in the burn p...

Page 31: ...Grey Grey Orange Orange White Grey Grey White Blue Yellow Auger Motor White Yellow Vacuum Switch Connect Thermostat Here Brown Brown Blue Purple Yellow Red Thermostat Combustion Blower Black Black Whi...

Page 32: ...uger Collar with Screw 50 968 14 Auger Motor 2rpm 50 2054 15 Exhaust Motor Capacitor including Strap 50 2053 16 Agitator Drive Shaft with Sprocket 50 1698 17 Motor Drive Sprocket 50 1700 18 Auger Moto...

Page 33: ...of 2 50 2294 54 Bearings with Mounting Bolts Set of 4 50 2295 55 M55C FPI Milan Empress FPI 2 Amp Small Fuse 50 2302 56 M55C FPI Milan Empress FPI 4 Amp Small Fuse Ignitor 50 2303 57 Agitator Drive B...

Page 34: ...2276 68 M55C FPI Cast Ash Door Chestnut 50 2282 68 M55C FPI Cast Ash Door DB 50 2299 69 M55C FPI Cast Surround Trim Only PD 50 2272 69 M55C FPI Cast Surround Trim Only Beach 50 2278 69 M55C FPI Cast...

Page 35: ...Parts Diagram Components 6 48 1 2 3 4 8 23 14 10 11 15 9 29 21 7 42 24 12 54 25 17 16 18 40 5 22 45 41 49 47 52 53 13 19 20 37 35...

Page 36: ...Parts Diagram Steel 69 70 38 28 57 26 27 63 5 62 61 36 51 59 66 67 68 64 65 30 37 39 44 36...

Page 37: ...Notes 37...

Page 38: ...Notes 38...

Page 39: ...cluding serial number Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caus...

Page 40: ..._____________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE ____________________________...

Reviews: