26
Slider
Damper
Exhaust
Channel
Exhaust Blower
Note:
Some parts
have been removed in order
to see components more clearly.
Figure 40: Slider / Damper
Installation
t
heRmoStat
i
nStaLLation
:
1. Install the wall thermostat in a location that is not to close too the unit but will effectively heat the
desired area.
Figure 39: Thermostat wire placement.
2. Install a 12 or 24 Volt Thermostat using an 18 x 2
gauge wire from the unit to the thermostat.
If the unit has been placed in the HI / LOW mode, the unit
will be taken to a low or idle setting when the thermostat
is not calling for heat. When the thermostat calls for
heat, the unit will go to the setting that is displayed on
the control board Heat Indicator. If the heating load is
not great enough when the stove is on low, the high limit
switch will turn the stove off and the switch will have to
be manually reset. To reset the high limit switch, remove
the right cabinet side. The switch is found behind the
control panel. Avoid setting off the high limit switch.
blower will decrease the vacuum pressure inside
the stove and as the heat output button is turned
down. The vacuum pressure inside the firebox
will increase as the combustion exhaust blower
increases in speed (higher heat output setting).
If the fire should happen to go out and the heat
output indicator has been set on the lowest
setting, the Slider Damper should be pushed in
slightly, decreasing the air in the firebox.
If, after long periods of burning, the fire builds
up and overflows the burn pot or there is a build
up of clinkers, this would be a sign that the pellet
quality is poor, this requires more primary air, the
slider damper must be pulled out to compensate.
Pulling the slider damper out gives the fire more
air.
S
LiDeR
/D
ampeR
S
et
-u
p
:
THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION, IT IS USED TO REGULATE
THE AIRFLOW THROUGH THE PELLET STOVE.
A Qualified Service Technician or Installer must set the Slider Damper
.
The slider damper is used to regulate the airflow through the pellet stove and is located behind the left
cab side (refer to Figure 40). The door must be open for the cab side to be removed on all models. On
freestanding model loosen the two T-20 torx screws, one above and one below hinge, swing open left
panel to access. On insert model remove the two (2) T-20 torx screws on the front, one above and one
below hinge, and the one T-20 at the top of the cab side under the top front.
The combustion exhaust blower is a variable speed blower controlled by the heat output button. This