Safety Warnings & Recommendations

CLEANING:

 There will be some build up of fly ash and small amounts of creosote in the exhaust. This 

will vary due to the ash content of the fuel used and the operation of the stove. It is advisable to inspect 

and clean the exhaust vent semi-annually or every two tons of pellets. The appliance, flue gas connector 

and  the  chimney  flue  require  regular  cleaning.  Check  them  for  blockage  prior  to  re-lighting  after  a 

prolonged shut down period.

ASHES:

 Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container 

of ashes should be on a non-combustible surface, well away from all combustible materials pending final 

disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they should be 

retained in the closed container until all cinders have been thoroughly cooled.

IMPORTANT:

 The door and ash drawer cover must be kept closed except during ignition, refueling and 

removal of residue material to prevent fume spillage.

GLASS:

 Do not abuse the glass by striking or slamming the door.  Do not attempt to operate the stove 

with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an ENVIRO 

dealer.  Do not attempt to open the door and clean the glass while the unit is in operation or if glass is 

hot. To clean the glass, use a soft cotton cloth and mild window cleaner, gas or wood stove glass cleaner, 

or take a damp paper towel and dip into the fly ash. This is a very mild abrasive and will not damage the 

glass.

ELECTRICAL:  The  use  of  a  surge  protected  power  bar  is  recommended. 

The  unit  must  be 

grounded. The grounded electrical cord should be connected to a standard 220-240 volts (2.92-3.18 

Amps), 50 hertz electrical outlet and also must be accessible. If this power cord should become damaged, 

a replacement power cord must be purchased from the manufacturer or a qualified ENVIRO dealer. Be 

careful that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces 

or sharp edges. This unit’s maximum power requirement is 7000 watts.

OPERATION:

 The door and ash drawer cover must be kept closed securely when the unit is in operation 

to prevent fume spillage and for proper and safe operation of the pellet stove. Also ensure all gaskets on 

the door are checked and replaced when necessary.  

CAUTION: 

When operating during adverse weather, if the unit exhibits dramatic changes in combustion 

stop using the unit immediately. 

INSTALLATION:

  Contact your local building or fire official to obtain a permit and any information on 

installation restrictions and inspection requirements for your area. All local regulations, including those 

referring to national and European Standards need to be complied with when installing this appliance.

Be sure to maintain the structural integrity of your home when passing a vent through walls, ceilings, or 

roofs. It is recommended that the unit be secured into its position in order to avoid any displacement. This 

appliance must be installed on a floor with an adequate load bearing capacity. If an existing construction 

doesn’t meet these prerequisite, suitable measures (e.g. load distributing plate) shall be taken to achieve 

it.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

Summary of Contents for OLYMPIAN

Page 1: ...NS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area OLYMPIAN F R E E S T A N...

Page 2: ...Vertical Rise with Horizontal Termination Installation Recommended Freestanding 16 Through Concrete Wall With Vertical Rise Installations Freestanding 16 Inside Vertical Installations Freestanding 17...

Page 3: ...ing a pellet burning appliance If it sounds the alarm correct the cause but do not deactivate You may choose to relocate the smoke detection devise within the room DO NOT REMOVE THE SMOKE DETECTOR FRO...

Page 4: ...wer bar is recommended The unit must be grounded The grounded electrical cord should be connected to a standard 220 240 volts 2 92 3 18 Amps 50 hertz electrical outlet and also must be accessible If t...

Page 5: ...e operation of the pellet stove Do not burn with insufficient combustion air A periodic check is recommended to ensure proper combustion air is admitted to the combustion chamber Setting the proper co...

Page 6: ...FPI 115 C 239 F Fuel Consumption High Fuel Consumption Medium Fuel Consumption Low FS 2 3 kg hr 5 07 lb hr FPI 2 2 kg hr 4 85 lb hr FS 1 4 kg hr 3 09 lb hr FPI 1 4 kg hr 3 09 lb hr FS 0 7 kg hr 1 54 l...

Page 7: ...m 24 3 4 629mm Figure 1 Olympian Freestanding Dimensions Figure 2 Olympian Fireplace Insert Dimensions Dimensions Fireplace Insert Specifications Dimensions Freestanding 7 23 3 4 604mm 12 7 8 326mm 22...

Page 8: ...ches 180 cm cross sectional area 5 This unit must not be installed directly onto carpet If it is to be installed on a carpeted area a solid surface wood metal or approved hearth pad must be installed...

Page 9: ...mpian on Floor Protection Minimum Width 36 914mm Minimum Height 48 1219mm Maximum Depth 30 762mm Back wall Side wall Adjacent wall 3 76mm 3 76mm 6 152mm Installation Clearances to Combustibles Freesta...

Page 10: ...our T 20 screws see Figure 10 The back height of this unit can be set to one 1 of three 3 heights 19 483 mm 21 537 mm 22 565 mm The hopper should be set to the maximum height that can be used in the i...

Page 11: ...Ensure the unit is electrically grounded to the chassis of your home permanently WARNING Do not install in a room people sleep in CAUTION The structural integrity of the manufactured home floor wall...

Page 12: ...ermination locations Table 2 Use in conjunction with Figure 13 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass top of plants wood or an...

Page 13: ...9 1 16 229mm Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes A Fresh air intake is strongly recommended for all installations Failure to install intake air...

Page 14: ...r of the exhaust pipe on the stove Extend that line to the wall Once you have located the center point on the wall refer to pellet vent manufacturer installation instructions for correct hole size and...

Page 15: ...cting the vent pipe to the unit s starter pipe Improper seals at the vent joints may cause combustion byproducts to leak into the room where installed seal as required Installation Figure 18 Straight...

Page 16: ...elbow may be used in place of the termination cap or stainless steel termination hood Through Concrete Wall With Vertical Rise Installations Freestanding A 45 elbow may be used in place of the termina...

Page 17: ...peted surface and space the unit in a manner so when the pellet vent is installed vertically it will be 3 76 mm away from a combustible wall 3 Locate the center of the fresh air intake pipe on the uni...

Page 18: ...a tee with clean out on the outside of the house 2 Install PL vent upward from the tee Make sure that you install support brackets to keep the vent straight and secure 3 Install ceiling thimble and se...

Page 19: ...ould com from chimney If holes already exist fresh air intake can be taken through back of the fireplace or through the ash dump Installation Hearth Mount Installation Freestanding Figure 24 Hearth Mo...

Page 20: ...r the gasketed opening in the stove where the exhaust motor was removed from 4 Install the exhaust blower motor in the Exterior Vent Housing Box onto the exhaust blower housing 5 Follow the procedures...

Page 21: ...y spaced and a small bead of high temperature silicone at each chimney connection Also ensure that all vertical vent sections are properly supported and that all clearances to combustibles are maintai...

Page 22: ...ation Outside Vertical Installations Freestanding Ensure that vent pipe is properly secured to wall using wall straps Maintain clearances to combustibles on vent pipe as well as unit Rain Cap Roof she...

Page 23: ...OT cut or modify any factory firebox parts If the fireplace insert does not fit into a zero clearance fireplace we recommend you use an ENVIRO freestanding model and install as a hearth mounted unit I...

Page 24: ...e Figure 31 REMOVAL When maintenance is required on the unit the surround must be removed Pull the surround straight up till it stops then pull it out about 4 10 cm and rest the surround on top of the...

Page 25: ...of trim Refer to Figure 34 Close both cab sides and replace the two 2 screws on each side REMOVAL OF TOP TRIM With door open undo the two 2 screws on the underside of the top there are visible under...

Page 26: ...7 Inner side of Olympian door Plated Door Installation TO AVOID PERSONAL INJURY DO NOT REMOVE OR REPLACE COVER WHEN PELLET STOVE IS HOT REMOVAL OF LOUVER BAR SET Door must be open The three 3 arrows i...

Page 27: ...inside the firebox will increase as the combustion exhaust blower increases in speed higher heat output setting If the fire should happen to go out and the heat output indicator has been set on the lo...

Page 28: ...t and has a higher possibility of the fire building up and creating clinkers hard ash build up Taking a reading of vacuum pressure inside the firebox with a magnehelic gauge can be used to set the sli...

Page 29: ...ealer for service 2 The stove will not operate when hot Check the Heat Level Indicator if a fire is not detected or if the fire has gone out the 3 light will flash because the Exhaust Temperature Sens...

Page 30: ...the vacuum switch if this corrects the problem check for above problems before replacing the Vacuum Switch Damage to gray wires between Circuit Board and Vacuum Switch Inspect wires and connectors Com...

Page 31: ...When the units system light becomes solid then control of the unit is given back to the operator If there is no control of the Heat Level button make sure the thermostat is calling for heat Call your...

Page 32: ...llow Yellow Grey Grey Grey Grey Purple Purple Blue 115V Black 220V Brown Black Black Black Blue Black Armor Cable Supplied Vacuum Switch Combustion Blower Optional Exterior Exhaust Blower Power Cord G...

Page 33: ...EF 018 Aluminum Hose Barb EF 019 7 Auger EF 025 Auger Brass Bushing Plate post January 2008 50 1780 8 Door Handle Complete EF 028 9 Glass Set with Tape EF 062 10 Slider Damper Plate EF 064 11 Brass A...

Page 34: ...0 825 30 Ash Pan Insert 50 826 31 Hopper Lid Insert 50 827 32 Hopper Cover Insert 50 828 33 300 Watt Ignitor 220V 50 1583 34 Circuit Board 5 Amp Fuses 220V Pair 50 834 Exhaust Starter Tube 80mm diamet...

Page 35: ...im 1 piece Antique Copper Freestanding 50 665 46 Upper Cabinet Trim 1 piece Painted Freestanding 50 666 46 Upper Cabinet Trim 1 piece Gold Freestanding 50 667 46 Upper Cabinet Trim 1 piece Pewter Free...

Page 36: ...OLYMPIAN Components January 2008 4 10 1 35 6 2 11 7 5 3 38 34 26 37 39 14 36 Parts Diagram Components 36...

Page 37: ...37 OLYMPIAN Freestanding Steel Parts September 2015 9 44 8 43 16 17 25 40 33 18 12 23 24 41 19 22 15 20 21 46 45 47 42 Parts Diagram Freestanding Steel...

Page 38: ...OLYMPIAN Insert Steel Parts September 2015 50 52 51 54 55 53 48 49 32 31 29 47 28 30 27 13 Parts Diagram Insert Steel 38...

Page 39: ...RCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE _________________________________________ NAME OF INSTALLER...

Reviews: