6
Specifications
r
ating
l
abel
l
ocation
:
Freestanding: The rating label is located on the inside of the hopper lid.
Fireplace Insert and Built-In Heater: The rating label is located on the hopper cover.
S
pecificationS
:
Table 1: Olympian Specifications.
Classi
fication
Testing Standar
d
Description
Class I IP-20
AS/NZS 4012:1999, 4013:1999
Residential W
ood P
el
let Heater
Vol
tage
Curr
ent
Fr
equency
220 - 240 V
2.92 - 3.18 Amps
50 Hz
Maximum P
ower R
equir
ement
Uni
t wi
th Ful
l Hopper
Hopper Capaci
ty
700W (2391 B
TU/hr)
~ 134kg (295lb)
~ 25kg (55lb)
Mean Flue Gas T
emper
atur
e - High
Mean Flue Gas T
emper
atur
e - Medium
Mean Flue Gas T
emper
atur
e - Low
FS: 233°C (451°F)
FPI: 220°C (428°F)
FS: 177°C (351°F)
FPI: 176°C (349°F)
FS: 119°C (246°F)
FPI: 115°C (239°F)
Fuel Consumption - High
Fuel Consumption - Medium
Fuel Consumption - Low
FS: 2.3 kg/hr (5.07 lb/hr)*
FPI: 2.2 kg/hr (4
.85 lb/hr)*
FS: 1.4 kg/hr (3.09 lb/hr)*
FPI: 1.4 kg/hr (3.09 lb/hr)*
FS: 0.
7 kg/hr (1.54 lb/hr)*
FPI: 0.
7 kg/hr (1.54 lb/hr)*
Heat/P
ower Output - High
Heat/P
ower Output - Medium
Heat/P
ower Output - Low
FS: 9.4 kW (32103 B
TU/hr)
FPI: 9.1 kW (31078 B
TU/hr)
FS: 5.3 kW (18100 B
TU/hr)
FPI: 5.8 kW (19808 B
TU/hr)
FS: 2.6 kW (8879 B
TU/hr)
FPI: 2.9 kW (9904 B
TU/hr)
Av
er
age P
articular Emissions (dry weight)
Av
er
age Emissions R
ate
Av
er
age Ef
ficiency
FS: 0.4g/kg
FPI: 0.5g/kg
FS: 26mg/MJ
FPI: 31mg/MJ
FS: 76%
FPI: 80%
Gr
oss Calori
fic v
alue of P
el
lets (dry weight)
Fuel t
ype
20.2 MJ/kg (8.68 B
TU/lb)
wood pel
lets - 6mm dia. - complying wi
th dr
aft standar
d A
S/NZS 4014
.6
*Note: Consumption wi
ll v
ary wi
th the t
ype of f
uel used.
IMPOR
TANT
: The abo
ve v
alues wer
e f
ound during testing and ma
y v
ary wi
th the f
uel t
ype, climate, and installation st
yle