background image

PRINCIPLE OF OPERATION CONT.

Trouble-free performance and minimum maintenance 
are  assured by the design features of the EnviroAire IAQ 
humidifier. All humidifier housing parts that come in contact 
with water are non-metal and will never rust or corrode. 
Neither heat nor water will affect them under normal 
operating conditions.

The Water Panel evaporator, designed especially for uniform, 
high evaporation, and the Scale Control Insert (which encases 
the water panel) effectively traps mineral deposits which are 
often the cause of damage to working parts in ordinary 
humidifiers. 

The Water Panel evaporator is the heart 

of the humidifier and must be in good condition to 

assure high capacity trouble-free performance. It 

should be changed at least annually.

The distribution tray incorporates a synthetic fabric liner that is 
designed to deliver water uniformly over the entire top surface 
of the water panel evaporator, provided the humidifier is 
mounted level. It is normal for some mineral deposits to form 
in the distribution tray as it dries out between humidification 
cycles. These deposits can actually help distribute water 
in the tray, but if they block the openings, they should be 
removed as described in the “Periodic Maintenance” section 
of this manual.

Your Digital Humidifier Control works in conjunction with 
your HVAC system to control the operation of the humidifier. 
The control senses indoor RH and outdoor temperature and 

automatically adjusts the operation time of the humidifier to 
provide the optimum humidity level in the home.

The Automatic Control can be set to turn on the HVAC blower 
when humidity is required. Plumbing the humidifier to hot 
water is required for this mode of operation.

The digital readout on the control displays the RH level inside 
the cold air return duct. RH is a measure of the amount of 
moisture in the air as a percentage of what the air can hold. 
Warm air can hold more moisture than cold air can. 

The control has lights which indicate humidifier operation, 
when the Water panel needs to be replaced and when 
service is required. See “Operating Instructions” for more 
information.

There are many humidifiers on the market. They all add 
moisture…with varying degrees of efficiency. None, 
however, offer the features, design, and performance 
incorporated into your new EnviroAire IAQ humidifier.

OPERATING INSTRUCTIONS 

The Digital Humidifier Control offers two modes of operation, 
Automatic or Manual. An explanation of both modes follows. 
(See the following page: Figure A for Automatic Mode. 
Figure B for Manual Mode.)

When in the Automatic Mode, this system offers the following 
benefits:

• You will always receive the optimum amount 

of humidity so that your home and its furnishings 

are always protected from the damaging effects 

of excess condensation or low humidity during the 

heating season.

 The Control automatically adjusts your 

home’s RH based on the outdoor temperature, increasing the 
time maximum comfort is maintained.

• Simple operation with few adjustments.

 The 

Control  eliminates the need to manually adjust the control 
when outdoor temperature changes. It also eliminates the need 
to turn the dial setting to “OFF” during the summer season.

Call Dealer for Service:

 The red light indicates that 

the humidifier is not operating normally and that service is 
required.

Change Water Panel: 

The yellow light indicates that it is 

time to change the Water Panel in the humidifier.

Humidifier On:

 The green light indicates that the humidifier 

is operating normally. 

DIGITAL CONTROL INDICATOR LIGHTS

Turn “Blower Activation Switch” to “ON” to allow the 
humidifier control to activate the HVAC fan for maximum 
humidification. For this setting the EA-755 must be connected 
to hot water. 

BLOWER ACTIVATION

Summary of Contents for Power EA-755

Page 1: ...Power EA 755 Humidifier Power Model EA 755 Humidifier Owner s Manual ...

Page 2: ...its from it Nature in producing an invigorating comfortable spring day combines just the right temperature and the right amount of moisture EnviroAire IAQ humidifiers employ the same principle with refinements to give you the optimum RH for maximum allowable comfort all winter long The important considerations in the evaluation of a humidifier are precise control sufficient capacity trouble free p...

Page 3: ...level inside the cold air return duct RH is a measure of the amount of moisture in the air as a percentage of what the air can hold Warm air can hold more moisture than cold air can The control has lights which indicate humidifier operation when the Water panel needs to be replaced and when service is required See Operating Instructions for more information There are many humidifiers on the market...

Page 4: ...on minor adjustments may be necessary This is dependent upon your home s construction Refer to TABLE 3 Operation Guide on the following page The RH in your home will now be accurately controlled to meet your needs and should not need further adjustment during future heating seasons Make note of the dial setting in the event you temporarily move the knob to OFF when performing annual maintenance of...

Page 5: ...e timer TEST RESET The Test Reset feature allows the humidifier operation to be checked even if there is no call for humidity See Check the Humidifier Operation ADDITIONAL INFORMATION Your humidifier is a precision system that will accurately maintain the RH in your home For every 2 F change in outdoor temperature the Digital Humidifier Control will automatically adjust the indoor RH by 1 The Digi...

Page 6: ...ccasion indoor moisture producing activities such as clothes drying cooking showers etc may raise the RH level higher than it should be even though the EnviroAire IAQ humidifier is not operating Telltale indications are condensation or frost on cold surfaces such as windows doors walls etc If such condensation persists for several hours your home should be ventilated to dissipate the potentially d...

Page 7: ...efore servicing 1 Note Humidifier Control setting and turn dial to the OFF position 2 Disconnect electrical power and turn off water supply 3 Unlatch humidifier front cover assembly 1 from base assembly 2 at the bottom of the cover lift and set aside 4 Pull out the Water Panel evaporative assembly 3 by grasping at the top and tipping out 5 Unsnap the distribution tray 4 from the scale control inse...

Page 8: ...ter than thirty 30 days after said five 5 year period by you to your original supplier together with the model number and installation date of the humidifier THIS WARRANTY SHALL NOT OBLIGATE ENVIROAIRE IAQ FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE HUMIDIFIER ITSELF IMPLIED WARRANTIES OF MERCHANTABILITY...

Reviews: