ADH SIROCCO SOFTWARE MAP
The software map below presents the major screens and user functions on the
ADH Sirocco automatic air dehydrator. The individual procedures in this manual
present one screen at a time as they will be seen during operation. This guide,
however, presents an overview of the screens and functions and provides
greater understanding than is possible from seeing only one screen at a time.
Note that all spellings are as shown on the unit display screen.
View Cfg / Edit Cfg
Save Can(cel)
Display
Alarms
Operat’n
Screen 2
Saver(s)
Brite 10
Keep Can
DCycl 50
SCTim 01
Alrm3Sel
Keep Can
Unit English
LALR 0.15P
LLIM 0.30P
HLIM 0.50P
HLRM 1.50P
Hum Sensor Y
Keep Cancel
To view the current settings only without changing them, select the View Cfg
option. To actually change the current settings, select the Edit Cfg option. Listed
below are the functions associated with each screen.
Select the Display option to:
change the screen saver time setting
change the brightness setting
Select the Alarms option to:
change the duty cycle alarm setting (DCycl)
change the short cycle time alarm setting (SCTim)
change the alarm relay #3 configuration (Alrm3Sel)
Select the Operat’n option to:
change the display unit of measure (Unit)
change the low pressure alarm level setting (LALR)
change the low limit target setting (LLIM)
change the high limit target setting (HLIM)
change the high pressure alarm level setting (HLRM)
configure the unit for the optional humidity sensor (Hum Sensor)