Wiring for Over 30 Amperes
•
Make sure that the power supply is turned off before wiring the device.
•
Use at least 14AWG stranded wire for power supply connections and at least 12AWG for runs greater than 10ft or 3m.
•
Connect the negative side of the power supply to both “DCV
-” terminals. Use two runs of wire into each terminal for
connections over 10ft or 3m.
•
Connect
the positive side of the power supply and the positive LED leads to both “DCV+” and both “LED+” terminals.
•
Connect the negative side LED wires to the terminals marked “R”, “G”, “B” and “X” for red, green, blue and white. Refer to
the DMX Address section below for more information.
Figure 2: Wiring Diagram for over 30 Amps