13
AFTER INSTALLATION THE END USER SHOULD
KEEP THIS GUIDE FOR FUTURE REFERENCE
DO NOT
THROW AWAY
Airflow Performance
Energy Usage
Setting
Power
(W)
Hours Run
Per Day
Energy Cost
p/a (£)
Total Energy Cost
Per Year (£)
Bathroom
on Trickle
1
22
1.20
1.97
Bathroom
on Boost
7
2
0.77
Kitchen
on Trickle
2
22
2.41
5.26
Kitchen
on Boost
26
2
2.85
Setting
Power
(W)
Duty (l/s)
Bathroom
on Trickle
1
9
Bathroom
on Boost
7
33
Kitchen
on Trickle
2
11
Kitchen
on Boost
26
52
Electricity cost of £0.15 per unit (kWh) and two hours of boost usage per day.
SELV variants run on bathroom duty only.