Cyclone 7

01423 859 395

SHOULD YOU ENCOUNTER ANY PROBLEMS 

INSTALLING THIS UNIT, CALL US ON:

Safety

Read and understand these instructions before beginning 

installation. The unit should be installed by a competent person.

Check there is space to fit the unit in your chosen location. As 

standard it can be installed using 100mm or 125mm inside diameter 

duct. With the optional adaptor, a 150mm duct can also be used.
The unit can be wall mounted as standard, or ceiling, recess, inline 

and window mounted using optional kits (see page 15 for further 

information). The unit cannot be wall mounted upside down (with the 

electronic boards at the bottom) as this will void the warranty.
Ensure the operation of the unit does not affect the operation of open-

flue appliances. If you are unsure, please consult local regulations 

or a qualified gas engineer. Consider the external cowl location in 

relation to open-flues from appliances e.g. boilers. You must ensure 

the cowl is positioned a minimum distance of 300mm away in all 

directions. 
In kitchens, if the unit is fitted above a cooker, it must be installed a 

minimum distance of 1 metre above any hob, and not have a pullcord 

fitted.
This unit is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities or lack of experience 

and knowledge, unless they have been given supervision and usage 

instruction by a person responsible for their safety. 
Children should be supervised to ensure they do not play with the unit. 

Cleaning and user maintenance must not be performed by children.

Summary of Contents for CYCLONE 7 230V Series

Page 1: ...CyClone 7 INSTALLATION GUIDE FOR ENGINEER INSTALLER SELV IPX5 230V IPX4 AFTER INSTALLATION THE END USER SHOULD KEEP THIS GUIDE FOR FUTURE REFERENCE DO NOT THROW AWAY ...

Page 2: ... the operation of the unit does not affect the operation of open flue appliances If you are unsure please consult local regulations or a qualified gas engineer Consider the external cowl location in relation to open flues from appliances e g boilers You must ensure the cowl is positioned a minimum distance of 300mm away in all directions In kitchens if the unit is fitted above a cooker it must be ...

Page 3: ...lied flexible cable not a solid core lighting and mains cable If any other type of cable is forced into the cable gland the unit will be damaged voiding the warranty If the mains cable is damaged it must be replaced by EnviroVent an authorized service agent or a similarly qualified person in order to avoid a hazard Do not remove or tamper with the electronic circuit boards inside the product The u...

Page 4: ... Cyclone 7 01423 859 395 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL US ON Diagrams Duct Adaptor Rear Carcass Impeller Front Cover 195mm 248mm Central Cartridge 148mm 193mm 78mm 99mm 56mm ...

Page 5: ...nect the N and L connectors of the fan power cable to the local isolator SELV 220V 240V 50 60Hz Mains Supply Local Isolator SELV Power Supply Connector Block The red 12V cable from the unit must be connected to the red cable on the SELV power supply using the supplied terminal block The black 12V cable from the unit must be connected to the black cable on the SELV power supply using the supplied t...

Page 6: ...se as humidity levels rise and decrease as humidity levels fall This intelligent function reduces energy costs motor wear and ensures a long life for the product Pullcord If your Cyclone 7 fan includes a pullcord it can be used to engage the maximum extraction rate for odour control Pull down on the cord to increase the unit to the maximum extraction rate Pull down again to decrease the unit back ...

Page 7: ...on the bottom of the unit leave the screws in place and remove the front cover 2 Pull the central cartridge out from inside the rear carcass 3 Disconnect the green connector end of the power cable from the unit then set the central cartridge to one side 4 Connect the power cable and local isolator to the Mains as in the wiring diagrams shown on page 5 Then tighten the cable gland on the rear carca...

Page 8: ...labelled fixing holes and the four screws and wall plugs provided 7 If using a backdraught shutter insert it fully The disc must open towards the outside of the property Do not fit this if the unit is ceiling mounted 8 Insert provided caps into the fixing holes at the top of the rear carcass 1 2 3 Not using these will void the IP rating and warranty 6 8 7 5 4 3 2 1 3 2 1 5 ...

Page 9: ...plied screws 11 To change unit settings adjust switches 1 and 2 on the central cartridge a Default 230V duty is kitchen humidity tracking b Default SELV duty is bathroom humidity tracking 9 10 11b SELV 11a 230V Switch 1 Left Humidity Tracking Right Two Speed Switch 2 Left Kitchen Duty Right Bathroom Duty Switch 1 Left Humidity Tracking Right Two Speed Switch 2 Not in use Bathroom Duty only L R 1 L...

Page 10: ... pad over the switches Not using this will void the warranty and IP rating 13 Ensure the impeller is fitted correctly the two clips should both be engaged 14 Replace the front cover ensuring the pullcord sits into the slot Then tighten the two screws The unit will not operate without the front cover in place 15 The mains supply can now be reactivated ...

Page 11: ...nt cover in place The unit will not operate until the front cover is fitted Does the pullcord activate Ensure the pullcord is not trapped inside the unit ON SITE INSTALLATION AFTER SALES SERVICE Please ensure that you have read and understood the installation instructions In the event of an on site installation problem or if you have any queries about the unit just call us and ask to talk to a mem...

Page 12: ...e centre then pull the impeller out 3 Clean the front cover and impeller in warm soapy water and allow to dry Use a damp cloth to clean any other parts of the unit Do not use solvents and do not clean any parts in a dishwasher appliance 4 Clip the impeller back into position ensuring the clips are engaged Replace the front cover and tighten both screws THE UNIT WILL NOT OPERATE UNTIL THE FRONT COV...

Page 13: ...otal Energy Cost Per Year Bathroom on Trickle 1 22 1 20 1 97 Bathroom on Boost 7 2 0 77 Kitchen on Trickle 2 22 2 41 5 26 Kitchen on Boost 26 2 2 85 Setting Power W Duty l s Bathroom on Trickle 1 9 Bathroom on Boost 7 33 Kitchen on Trickle 2 11 Kitchen on Boost 26 52 Electricity cost of 0 15 per unit kWh and two hours of boost usage per day SELV variants run on bathroom duty only ...

Page 14: ... unit will operate at the maximum extraction rate It will remain at this rate until the switch is deactivated Two Speed Only The unit is available in a two speed variant without humidity tracking These units run at a constant trickle or boost speed as required by the user To pair additional remote control switches 1 Turn the unit off at the isolation point 2 Restore power for 20 seconds from resta...

Page 15: ...break down that arises due to faulty materials or construction Please note that a receipt will be required as proof of purchase Units bought from an unapproved source including but not limited to auction websites are not covered by this warranty Your fan serial number For warranty conditions and exclusions visit www envirovent com warranty What should I do if I have a problem You should not disman...

Page 16: ...mportant to us as we strive to improve our products services and overall customer experience Please email us to help us serve you better feedback envirovent com Delivering innovative and sustainable ventilation solutions worldwide AFTER COMPLETING INSTALLATION PASS THIS GUIDE ONTO THE END USER FOR FUTURE REFERENCE DO NOT THROW AWAY Boxed unit weight 230V 1 65 kg SELV 1 85 kg Unboxed unit weight 23...