ATTENTION: When the humidity rate is above the selected value, the
automatic option takes precedence over the manual and the unit cannot then
be switched off using a switch.
The desired humidity level and time delay are set by means of adjuster positioned
on the printed circuit board (fig.10) and accessible once the grille (1) is removed.
The humidity is set by the
adjuster “%HR”:
-
To increase the humidity setting turn anticlockwise (min.60 %)
-
To reduce the humidity setting turn clockwise (max. 90 %)
The timer
is set by the adjuster “t min.”:
-
To reduce the "run on" time, turn anti-clockwise (min. 2 minutes)
-
To increase the "run on" time, turn clockwise (max: 20 minutes).
CLEANING AND MAINTENANCE
IMPORTANT: DISCONNECT FROM THE MAINS SUPPLY BEFORE CARRYING
OUT CLEANING AND MAINTENACE
To ensure optimum performance from your extract fan, it should be cleaned
regularly by a competent person.
AFTER SALES SERVICE
We recommend you not to dismantle or remove any other parts than those
mentioned, as any tampering would automatically cancel the guarantee. If you
detect any fault, contact EnviroVent on 01423 810810.