SILENT-100 DESIGN AXIAL EXTRACTOR FANS 
Suitable for bathroom applications 

 

INSTALLATION 

 

This  fan  is  IP45  rated  and  is  suitable  for  application  in  zones  1  and  2  with  RCD 
protection. 

IMPORTANT:  Before  installing  and  wiring  the  unit,  ensure  that  the  main 
supply is disconnected. 

 
SILENT-100 DESIGN should only be used in conjunction with fixed wiring. 
 
Fig. 1:  

1: Protection grille 
2: Connection terminals 
3: Outlet with backdraught shutter 
4: Cable entry 

 
The  SILENT-100  DESIGN  is  suitable  for  wall  or  ceiling  mounting  and  can  either 
extract directly to the outside or via an individual ducted system (see Fig. 2). 
The unit should be mounted on the wall or ceiling using the 4 rawl plugs and screws 
provided. 
 
Make a hole in the wall or ceiling of 105 mm dia. 
If the unit is to be installed with individual ducting, use a standard 100 mm dia. duct. 
Ensure that there are no obstructions to the airflow and that the impeller turns freely. 
 
Fix  the  extractor  to  the  wall  in  such  a  way  that  it  is  not  distorted  in  order  to  avoid 
noise  generation  or  problems  with  the  rotation  of  the  impeller.  Make  sure  that  the 
backdraught  shutter  opens  freely  and  has  not  being  damaged  in  transit.  Introduce 
the mains cable through the cable entry (4) and fix it to the wall.  
 
Connect the electrical wiring as set out below and then mount the protection grille. 

 

WIRING 

 
The  SILENT-100  DESIGN  is  an  extractor designed for a single phase supply, with 
voltage  and  frequency  as  indicated  on  the  rating  plate  of  the  unit.  The  units  are 
manufactured  with  double  electrical  insulation  (Class  II)  and  therefore  they  do  not 
need an earth connection. 
 
The electrical installation must include a double pole switch with a contact clearance 
of at least 3 mm. 
 
The electrical cable must enter the SILENT-100 through the cable entry (4). 

Summary of Contents for Silent-100 Design

Page 1: ...SILENT 100 DESIGN Instruction leaflet...

Page 2: ...make sure that the product corresponds to the one you have ordered and that the detail on the instruction label fulfil your requirements IMPORTANT BE SURE TO HAVE READ AND UNDERSTOOD THESE INSTRUCTION...

Page 3: ...Fig 1 1 4 3 2...

Page 4: ...Fig 2...

Page 5: ...Fig 4 Fig 3 L N L N Ls L N L N Ls...

Page 6: ...L N Fig 7 Fig 6 Fig 5 L N Ls L N Ls T min L N SILENT T...

Page 7: ...Fig 10 Fig 9 Fig 8 T min HR L N L N Ls L N L N Ls SILENT HT...

Page 8: ...ual ducting use a standard 100 mm dia duct Ensure that there are no obstructions to the airflow and that the impeller turns freely Fix the extractor to the wall in such a way that it is not distorted...

Page 9: ...the timer turn the potentiometer on the printed circuit board as fig 7 To reduce the run on time turn anticlockwise min 1 minute To increase the run on time turn clockwise max 30 minutes SILENT 100 H...

Page 10: ...CE IMPORTANT DISCONNECT FROM THE MAINS SUPPLY BEFORE CARRYING OUT CLEANING AND MAINTENACE To ensure optimum performance from your extract fan it should be cleaned regularly by a competent person AFTER...

Page 11: ...ted within this booklet In the event of any failure of the fan within five years of supply excluding only wilful or careless damage we will exchange the fan free of charge EnviroVent Ltd Envirovent Ho...

Page 12: ...EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate Hg2 8PA 01423 810 810 www envirovent com info envirovent com Ref 9023012001...

Reviews: