D4K Pro® User Manual
D4K_UserManual_v1.3_EN.docx, 2021-02-12
Page 14 of 52
4.4
Intended Environmental Conditions
4.4.1
Environmental Conditions for Printers
•
Ensure that the room temperature does not fall below 23°C or exceed 28°C. Generally, the ideal working temperature
is around 23°C or 73 °F.
•
Humidity is not to exceed 60%.
•
Do not set up the printer in humid or dusty places or in places where it may come into contact with smoke or steam.
That is very important for getting usable build results.
•
Do not expose the printer to direct sunlight or any other UV radiation.
•
The room must be temperature controlled to ensure the correct operation of the printer.
•
Air conditioning units should be at least three meters away from the printer with no airflow pointing directly at the printer.
•
Do not place the printer near to any door way, avoid temperature drops.
•
Room must allow heat generated from the system to dissipate at 0.03 m³/min airflow.
•
Keep the printer away from water sources such as sinks, tubs, wash stations, etc.
•
Do not place the printer near polishing stations
.
Protect the printer’s internal components from dust.
4.4.2
Storage Conditions for Photopolymers
Photopolymers should be stored under the following conditions:
•
at room temperature
•
dry
•
in closed bottles
•
lightproof
If photopolymers are filled in the material tray, the printer door should always be closed. If you don’t need the material tray for a
longer time, pack the material tray and store it under the same conditions as mentioned above.
NOTICE
Follow the temperature instructions for each material that is being used
.
These instructions can be found:
•
On the label of the material bottle
•
Extended instructions are located in the material handling guide on the provided USB-drive in the Starter Kit
of the printer.
NOTICE
More specific storage conditions for photopolymers can be found in the appropriate cookbooks or Instruction of
Use provided by manufacturer or distributor.