www.enware.com.au
Call 1300 369 27 13
BOTTLE FILLER - DOME ADJUSTMENT
Adjust the position of the dome if:
-
there is play on the handle that needs to be adjusted;
-
if the tap is not shutting off completely / water constantly running; or
-
if there is no water flow
Adjust the dome by carrying out the
following steps:
1. Using a 3/32” or 2.5mm Allen key, undo
the grub screw located on the side of the
dome cover near the hex.
2. Unscrew the dome from the SBA slowly.
The water flow should stop.
3. Now this time, screw the dome into the
SBA. Water should begin to flow from the
outlet.
4. At this point, unscrew the dome just
slightly by approx. 1/4 to 1/2 a turn - the
water should stop flowing from the outlet.
This is the ideal position of the dome.
If the dome is screwed in too far, the handle will push the SBA piston down and let water
through constantly. If the dome is wound too far out, the handle will have too much play
and will feel loose.
5. Once the correct dome position is achieved, install the grub screw ensuring it is tightened
square against one of the SBA flats underneath to maximize vandal resistance.
6. Re-test the tap for correct operation.
7. If problems persist, refer to TROUBLESHOOTING.