www.enware.com.au
Call 1300 369 27 17
troubleshooting
WATER CHILLER
PROBLEM
CAUSE
RECTIFICATION
No water at outlets
Water not connected or turned
off
Connect and turn on water supply
Water frozen
Adjust water temperature control on
thermostat to higher setting. Do not
operate the appliance, until ambient
temperature is again above 0°C and
frozen unit has completely thawed.
Water not cooled
Power is not connected
Turn power supply on
Fan ventilation not adequate
Ensure there is gap behind back of
chiller to allow air flow from vents
Temperature setting too high
Adjust water temperature control on
thermostat to lower setting
Poor water flow at outlets Bubbler stream is not adjusted Adjust bubbler stream
Carafe filler handle is too loose Adjust carafe filler adjusting nut and
handle
Carbon filter is blocked
Replace carbon filter
Water leaks at outlets
Bubbler cartridge is damaged
Replace bubbler cartridge. Ensure
water pressure is below 500kPa
Carafe filler handle is too tight
Adjust carafe filler nut and handle
Water tastes foul
Carbon filter has been
contaminated
Replace carbon filter
Water in tank is stale
Purge water in tank by running the
bubbler for 5 minutes
BUBBLER
PROBLEM
CAUSE
RECTIFICATION
Water runs constantly
from
bubbler outlet
Debris in cartridge
Replace cartridge BUB294
Cartridge has been damaged
Replace cartridge BUB294
Seating washer damaged or
spring broken
Install a pressure reduction valve.
Replace cartridge BUB294
No flow from bubbler
outlet
Water supply turned off
Turn water on
Debris fouling inlet or outlet
ports of cartridge
Remove blockage
Rubbish/debris fouling outlet
Remove blockage
Water discharge from top
of bubbler
Cartridge is damaged
Replace cartridge BUB294