www.enware.com.au
Call 1300 369 27
7
5. Turn the water supply on and purge the air from the
stainless steel chilling tank by pressing the push button
on the bubbler or turning on the bottle filler. Water may
spit from the outlets during this procedure and care
should be taken not to let water splash on walls and
furniture. Allow the water to flow for 5 minutes, starting
and stopping it frequently.
6. Check all plumbing for leaks. Check the bottle trap and
drain pipe connections for water-tightness.
7. Replace the front panel to the chiller unit.
8. Connect power cable to an electrical outlet.
(Electrical connection: a flexible 2m service lead, 3 pin
10 AMP plug supplied to connect the chiller to a 240V
50Hz AC supply.)
Turn power on. The refrigeration unit and the fans should
start to activate.
9. Once water is cooled and chiller function is checked,
turn off the power and disconnect the power cable.
Open the front panel and check all plumbing for leaks
once again.
IMPORTANT - Chiller unit must be disconnected
from power supply before accessing the inside of
the chiller unit.
10. Replace front panel of the water chiller and secure
the panel using screws provided.
Connect power cable and turn power back on.
Remove protective film from stainless steel panels.