Setting Date and Time

To set-up the date and time, the user has to be set up first

User Set-up

Press the ‘SET” button to activate the set-up process. 
The user number appears and flashes. 

Press the ’Memory’ button to select a user and the press “SET” button to confirm the user.
When the User is set up, the “Year” icon will start flashing to prompt to set the year. Press the  ‘MEMORY’ button 
continuously until the desired year appears. Press  ‘SET’ button to set the year.
Now the ‘Month’ icon will start flashing. Press the ‘Memory’ button continuously until the desired month appears. 
Press the ‘SET’ button to set the month. When the month is set, the “Date” icon will start flashing. Press the ‘Memory’ 
button continuously until the desired date appears. Press the ‘SET’ button to set the date. similarly set the hour and 
minute.

Once the year , month, date and time is set, press the ‘Memory’ button and select the measurement unit: “mmHg” or 
“kPa” and press the ‘SET’ button to set the measurement unit.

Using the Cuff

Both left and right arms can be used to measure. Usually the left arm is used. 
Keep your wrist bare or only wear thin and close-fitting clothes when measuring.
Measure in a room with favorable temperature.
Don’t roll you sleeves up or measure when wearing thick clothes, but perform measurement after removing off your 
heavy clothes.
For accurate measurement, please pay attention to position the arm band correctly.

Connect the air plug to the connector on the monitor
Sit on a chair with your feet flat on the floor. Place your left 
arm on a table so the cuff is level with your heart.
Insert your left arm through the arm band.
Place the air tube on the palm and turn your palm upward

Rotate  the cuff so the metal stripe is on the inside of your arm and aligned with your middle finger. The air 
tube runs down the inside of your arm. The bottom of the cuff should be approximately 1/2" above your 
elbow. 

Wrap the cuff firmly in place around your arm using the cloth fastener.

1.
2.

3.
4.

5.

6.

4

Summary of Contents for EOC -SBPBT-L

Page 1: ...User Guide Digital Blood Pressure Monitor EOC SBPBT L EOCENE HEALTH SYSTEMS ...

Page 2: ...n it as well Note Illustrations in this manual is solely for interpretation purposes only Table of Content Safety Information What is in the Box Battery Installation Replacement Setting Date and Time Using the Cuff Correct posture Measuring blood pressure Using the Memory Function Care and Maintenance Product declaration Error display Interpretation When you have queries Specifications Product war...

Page 3: ...dismantle or repair the device or the cuff there is no user serviceable parts in it Use only 1 5 V Volt alkaline batteries for this device Using other type of batteries may damage the unit Ensure the batteries are inserted in to the battery compartment with the correct polarity If battery fluid gets in to your eyes rinse with plenty of water and contact a physician immediately When the Low battery...

Page 4: ... measurement unit mmHg or kPa and press the SET button to set the measurement unit Using the Cuff Both left and right arms can be used to measure Usually the left arm is used Keep your wrist bare or only wear thin and close fitting clothes when measuring Measure in a room with favorable temperature Don t roll you sleeves up or measure when wearing thick clothes but perform measurement after removi...

Page 5: ...p click on the Eocene icon and register yourself by selecting Registration as shown in the figures 1 below Input the requested information as shown in figure 2 and complete the registration Once you are registered you can log in by selecting Log in as shown in figure 1 1 2 3 4 Figure 1 Figure 2 After logging in on window that appears select Blood Pressure as shown in figure 3 The new window that o...

Page 6: ...itor be checked and calibrated once a year to ensure normal functioning and accurate measurements There is water or the possibility of water being splashed on the Monitor The device is exposed to direct sunshine high temperature humidity dust and corrosive gas There is a possibility of subjecting the Monitor to vibrations or impact Chemicals or corrosive gases are stored i ii iii iv The blood pres...

Page 7: ...exhaust Er H Machine operation error can t receive signal Turn off the power and power on to measure again 1 Er cuff winding too loose Please wind the cuff tighter again Er1 Cannot measure pulse signal is weak cannot get effective measuring results Er 2 Too much interference move speak magnetic etc when measuring 2 Er Talking when measuring or rocking arm causes interference Keep your arm steady a...

Page 8: ...cuff Cuff exhausts in a short time Cuff is wound loosely When the cuff is wound loose it adds pressure to the cuff and reduces its service life The device works properly and the measurements are accurate but when Blood pressure was measured in the hospital the readings were lower than the ones measured at home You must have taken hypotension drugs or the cuff was not positioned correctly Hypotensi...

Page 9: ...Operation Electronic Blood Pressure Monitor EOC SBPBT L Digital display Oscillometry 120 W x 158 L x 54 H 1 04 LBS Pressure 3mmHg g Pulse 5 1mmHg 0 1Kpa 40 beat min 200 beat min 0 280 mmHg 0 37 3Kpa 40 180 pulse min 60 sets Time display Auto off Touch button Batteries Storage condition Bluetooth Communication distance Cuff Sizes 4xAA Batteries temperature 20 55 C humidity 15 95 RH 10m 30F barrier ...

Page 10: ... User operated the device not in accordance with the guidelines provided in the user manual 5 Repair or maintenance done by an unauthorized personnel or establishment Service provided outside the scope of warranty will be charged as per prevailing regulations and stipulated rates For warranty services please contact Eocene Systems 2441 Bellevue Avenue Daytona Beach FL 32114 Support 321 567 0688 FA...

Reviews: