The booth lighting and wiring must be "splash-proof" and
suitable for an ambient temperature of 140°C.  Only a VDE-
tested sauna light with max. 40 watt should be installed in
connection with the sauna oven.

l

The sauna unit (sauna oven, controller, lighting, etc.)
should be connected only by a locally registered electrical
contractor using of a fixed mains connection.

 All connection

cables laid in the interior of the booth must be suitable for an
ambient temperature of at least 140°C (e.g. silicon cable).  If
single-core cables are used as connection cables, they must
be protected by a flexible metal tube.  For the minimum
diameter of the connection cable and the appropriate booth
size in relation to the connection capacity in kW, see Table 2.

l

When assembling the sauna oven, attention must be paid to
the fact that the vertical distance between the upper edge of
the oven and the sauna roof must be at least 90 cm, and the
horizontal (lateral) distance between the oven and the booth
wall at least 4 cm (Fig. 1).  The distance between the lower edge
of the oven and the floor must be at least 16 cm.  Special care
must be taken to ensure that the oven does not rest on the floor.
Appropriate floor coverings for the sauna area include ceramic
tiles.

l

The distance between the oven protective grille and the sauna
bench or other combustible materials must be at least 4 cm
from the oven.  The height of the oven protective grille should
approximately corresponde to the height of the front of the
oven.

booth wall

oven protective
grille

4 cm

4 cm

38 cm

4 cm

Fig. 1

Circuit diagrams

9000 W

U V W N

400 V AC 3N

7500 W

1500 W

1500 W

1500 W

1500 W

1500 W

1500 W

45 cm

Connection example for sauna
installation

Note: Always clamp on neutral
conductor N as well

To be used with controllers type

4535 F
4590 D 24
EMOTEC H9003

or per the sauna-booth manu-
facturer's specifications.

6 kW when occupied with
1.5 kW heat rods

6 kW when occupied with
2 kW heat rods

2000 W

2000 W

2000 W

6000 W

6000 W

1500 W

1500 W

1500 W

1500 W

1500 W

1500 W

1500 W

1500 W

1500 W

7500 W

2500 W

2500 W

2500 W

7.5 kW when occupied with
1.5 kW heat rods

7.5 kW when occupied
with 2.5 kW heat rods

Caution!
Always make certain to
include neutral conductor
N clamp

Summary of Contents for Bi-O Tec

Page 1: ...MADEINGERMANY Druck Nr 29342448 47 04 20012959 Bi O Tec IP x4 MONTAGE UND GEBRAUCHSANWEISUNG ASSEMBLY INSTRUCTIONS AND INSTRUCTIONS FOR USE INSTRUCTIONS DE MONTAGE ET D EMPLOI...

Page 2: ...mbetragen Grunds tz lichistzubeachten da derOfennichtaufdenBodengestellt werdendarf Zweckm igeBodenbel geimSaunabereich sindKeramikflieseno l DerAbstandzwischenOfenschutzgitterbzw Liegebankund anderen...

Page 3: ...achau enzum Steuerger t Abb 2 AuchanderKabinenau enseitesolltedas Kabel sowiealleanderenAnschlu kabel ZuleitungzumNetz undzurKabinenbeleuchtung vorBesch digunggesch tztwer den z B durchVerlegunginInst...

Page 4: ...bsform ist der Verdampfer nicht in Betrieb Esistunbedingtdaraufzuachten da keineKr uteroderEssenzen in der Kr uterschale sind denn diese k nnten durch berhitzung entflammen Essenzen bzw Aufgu mittel n...

Page 5: ...rmangelan WollenSieIhrSauna badtrotzdemfortsetzen sok nnenSieWasserindenVorratstank zugeben nachdem das Steuerger t zuvor 5 Minuten auf Stop oder5Minutenauf FinnischeSauna gestelltwar DerHeizstabim Ve...

Page 6: ...izger ten ist die DIN VDE 0100 Teil 703 zu beachten Diese Norm macht in Ihrer neuesten Ausgabe g ltig seit Juni 1992 unter nderungen Absatz f folgende Aussage Zitat Die Forderung nach Fehlerstrom Schu...

Page 7: ...tion and air venting must be installed in each sauna booth Theventilationopeningsmustalwaysbepositioned behindthesaunaoven 5 10cmabovethefloor SeeTable 1fortheminimumventilationandair ventingmeasureme...

Page 8: ...ancebetweentheloweredge oftheovenandthefloormustbeatleast16cm Specialcare mustbetakentoensurethattheovendoesnotrestonthefloor Appropriatefloorcoveringsforthesaunaareaincludeceramic tiles l Thedistance...

Page 9: ...by being laid in installation tubes or by applying wood covering panels Fig 3 Fig 2 Connection box Distance holder Connection clamp Cable screwing Wall feeding into a blank tube Air supply opening Fig...

Page 10: ...out4Lofwaterintothewatercontainer i e enoughforasauna sessionlasting2 3hours Regulatethehumidityatthecontroller Never add essences ethereal oils or herbs to the water but rather into the herb dish on...

Page 11: ...on switch is to be installed no further electrical receiving parties are to be fused via this FI protection switch With current technology there is no need to use vapour tight tubular radiators for sa...

Page 12: ...r of transport damage to our service department Alwaysincludethecompletedwarrentycertificatewhenreturning equipment Possible shipping costs arising from the transport to and from point of repair canno...

Page 13: ...nedusaunadoitoffrirunehauteurint rieurede1 90 mminimum l Danslacabinedusaunaseramont ununiquepo leoffrant lapuissancedechaufferequise voirletableau2 l Pr voir des orifices d entr e et de sortie d air...

Page 14: ...que I cart verticalentreI ar tesup rieurdupo leetleplafonddusauna soitde90cmminimum et cequeI carthorizontal lat ral entre le po le et la paroi de la cabine soit de 4 cm minimum fig 1 L cart entre I...

Page 15: ...tre pos s prot g s de taus d g ts Passez les par ex dans des tubesd installation lectriqueourecouvrez lesavecdeslamesen bois Fig 3 Fig 2 Coffret de branchement Ecarteur Bornes de raccordement Raccord...

Page 16: ...rant ATTENTION D brancheztoujoursI appareildusecteuravantd effectuerles travaux de nettoyage ou d entretien avant de changer des pi ces ou des accessoires ou avant de supprimer des d rangements pendan...

Page 17: ...actuel les r sistances de chauffage ne peuvent tre fabriqu es sans que l air ambiant ne les rende humide Ceci peut provoquer un courant de d faut instantan ment lev lors du chauffage Si le disjoncteu...

Page 18: ...min s En cas de recours en garantie veuillez renvoyer I appareil accompagn de son certificat de garantie et de la facture au service Pour toutes r clamations dans la garantie en dehors de l Allemagne...

Page 19: ...19...

Reviews: