Connections
General instructions for electrical installation
Ensure that electrical installation is performed in compliance with the standards and legal norms
valid in your country.
If a residual current device (RCD) is installed, ensure that there are no other electrical consumers
not belonging to the sauna system which are fused via this RCD.
If the sauna heater has not been used for an extended period of time, the heater may draw mois-
ture from the ambient air, which, in rare cases, could lead to the RCD to be tripped. This is a physical
process and not a fault on the part of the manufacturer.
In this case, the heater must be heated by a technician under supervision which will bypass the
RCD function. Once the moisture has escaped from the heating elements after approx. 10 minutes,
the RCD can be integrated again in the electric circuit.
If the sauna heater will not be used for an extended period of time, we recommend that you switch
on the heater every 6 weeks so that the heating elements do not accumulate moisture. If, during
commissioning, the RCD is triggered, the electrical installation must be checked again
The electrician is responsible for properly connecting the heaters; thus, the manufacturer does not
assume liability.
Connections
The sauna control unit, the output controller, and the heater must be connected as shown in the
circuit diagrams.
Please observe the installation and operating instructions for the control units and output con-
trollers.
Connections