 Electrical connection

  Start-up

Either you just plug in the device or you can 
use a coin box

.

The connection of a coin box is documented 
in the connection diagram on the last page of 
the instructions.

Recommended  exposure  distance: 
approx. 1.40 m

ca. 1,40 m

Cleaning of the radiators 

Use a damp cloth for cleaning of the unit. 
Never  use  corrosive  cleaning  substances 
(solvents, acids, etc.). Use water with soap 
when necessary.

Important: Make sure that no moisture 
gets on the IR-radiator or terminals

The line connection may be carried 
out only by a qualifi ed electrician .

Fig. 7

Fig. 8

Fig. 9

Power cord (enclosed)

connecting 
leads

Attach the connecting leads to 230 V.

The InfraSky 3000 has to be permanent con-
nected at 230 V.

Because of the higher starting current has the 
unit to be fused by a 16A circuit breaker with 
K characteristic.

Put the enclosed  power cord into the connec-
tor at the top of the tanner.

approx. 1.40 m

 Maintenance and  servicing

Disconnect  the  system  from  the 
power source before servicing or 
other works.

Be  aware  that  loungers  made  of 
certain types of plastic may get de-

formed or damaged due to the prolonged 
exposure to heat.

Fig. 6

Connector for 
power cord

Connection  for 
coin box / timer

Summary of Contents for InfraSky 3000

Page 1: ...1 D IP20 Druck Nr 29343629en 28 12 InfraSky 3000 GB Assembly and operating instruction...

Page 2: ...cal connection 4 Start up 5 Maintenance and servicing 5 Cleaning of the radiators 5 Replacement of the IR radiator 6 Troubleshooting 6 Spare parts 6 Specification 6 Connection diagram 7 Service Addres...

Page 3: ...expe rience and or knowledge unless these persons will be supervised by persons responsible for their security or in case they have been instructed how to use this device Children are not aware of the...

Page 4: ...t the faces are 3 assembly angles each with attached Velcro fasteners Velcro fasteners Schrauben Fig 1 Fig 2 Fig 4 Fig 5 Fig 3 Fig 6 Now press the side covers to the Velcro fasteners Velcro fasteners...

Page 5: ...ne connection may be carried out only by a qualified electrician Fig 7 Fig 8 Fig 9 Power cord enclosed connecting leads Attach the connecting leads to 230 V The InfraSky 3000 has to be permanent con n...

Page 6: ...ily removed from its position Now remove the protection grill from the face side of the unit To replace a radiator unscrew and remove the large cover of the terminal block 4 screws Replacement of the...

Page 7: ...zautomat Connection Timer or coin box Time N L external 500 W 500 W 500 W 500 W 500 W 500 W Strahler 1 Strahler 2 Strahler 3 Strahler 4 Strahler 5 Strahler 6 A2 A1 7 5 3 1 8 6 4 2 K1 Hauptanschlu Bu1...

Page 8: ...umber and model name with detailed description of the fault This guarantee covers defective parts and labour but not the defects caused by wear and tear In case of complaint please return the equipmen...

Page 9: ...ng articles or missing ac cessories He will discuss with you the individual case and try for immediate and customer friendly so lution For economic returns within Germany you will get an RMA number fr...

Reviews: