Dry Finnish sauna operation

In this mode the vaporizer is not in use. 

It is 

imperative to ensure that there are no herbs 

or essence in the holder, because they could 

dry out and catch fire.

 Essences or any other 

kind of additives to be added to the water shall 

be used only according to the manufacturers 

instructions. 
By water infusion do not pour the water too 

quickly over the rocks, pour them slowly with 

the sauna ladle. This ensures that the water 

vaporises completely so you can enjoy the full 

effect of „loylu“ (water infusion).

Never add more sauna essenses or additives 

to the infusion water than indicated on the 

pack. Never use alcohol or undiluted infusi-

ons. Danger! There is a risk of fire.

 

Attention:

 Pour the infusion 

water only on the sauna rocks 

and never anywhere else.

When using your sauna in a 

dry Finnish mode never add 

sauna essences or place any herbs 

into the vaporizer holder for es-

sences/herbs. 

Risk of fire!

Humid sauna operation 

 

only for „Vapor“ model with vaporizer

The Mythos Öfen are optionally available with a 

2 kW or 3 kW vaporizer, which may be attached 

to the heater on the right or left side.

For all details concerning instalation, connec-

tions, operation and maintenance please refer 

to the separate manual „Mythos vaporizer“.
Please consider that for the operation of the 

vaporizer you will need an appropriare sauna 

control unit supporting dry and humid sauna 

operation modes.

Summary of Contents for Mythos S34

Page 1: ...1 D MADE IN GERMANY Mythos S34 S45 print no 29344483en 05 13 GB Installation and operation manual sauna heater Image above shows optional equipment...

Page 2: ...S45 Vapor 7 Installation Scope of delivery 8 Specifications 8 Minimum clearances 8 Heater foot sealing installation 9 Cable connections 9 Installation of Cubic stones 9 Dry Finnish sauna operation 10...

Page 3: ...ed the goods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater and the control unit are aligned to each other Please o...

Page 4: ...resin and untreated materials e g spruce Only one sauna heater with the required heating output may be installed in the sauna cabin Please provide air intake and vent openings in each sauna cabin The...

Page 5: ...a flexi ble metal tube connected to the equipment grounding conductor Please see the table for the mi nimum cross section of the con nection cable and the suitable cabin size in relation to the power...

Page 6: ...tion with a protective cover or S guard system if operated by remote control Remote control Setting control and or regulation of the device by means of commands entered when the de vice is out of sig...

Page 7: ...ater Connection power extension heater Connection controller power extension unit 7 5 kW 3N AC 50 Hz 400 V 3 x 16 5 x 2 5 5 x 1 5 9 0 kW 12 0 kW 3 x 16 5 x 2 5 5 x 1 5 4 x 1 5 15 0 kW All cross sectio...

Page 8: ...trol unit ECON EMOTEC 4 5 3 optional 5 Netz Main LSG 5 5 5 4 5 4 Saunasteuerger t control unit ECON EMOTEC 3 optional 4 Netz Main 7 5 9 kW 12 15 kW Vaporizer power Electrical connection Vaporizer wate...

Page 9: ...5 or 9 0 kW Mythos S45 12 0 or15 0 kW depending in the model Height 840 mm Width S35 420 mm S45 500 mm Depth 370 mm Stone filling S35 35 kg S45 45 kg Leakage current max 0 75 mA per kW heating power S...

Page 10: ...ards and shall be drawn along the foot to the sauna controller LSG unit Illust 4 Illust 3 Mythos S45 Mythos S35 Optional Cubic stone sets For Mythos S35 item 94 5520 For Mythos S45 item 94 5521 The op...

Page 11: ...an indicated on the pack Never use alcohol or undiluted infusi ons Danger There is a risk of fire Attention Pour the infusion water only on the sauna rocks and never anywhere else When using your saun...

Page 12: ...tones will re heat suffici ently again Never add more essences or volatile oils than advised on the pa ckaging Never use alcohol or un diluted concentrates Caution Fire hazard All sauna heating units...

Page 13: ...ical units will be protected by this ELCB Under current manufacturing technology it is not reasonable to use heating elements for sau na heaters which do not collect moisture from the surrounding air...

Page 14: ...mber and model name with detailed description of the fault This guarantee covers defective parts and la bour but not the defects caused by wear and tear In case of complaint please return the equip me...