Doc:
Issue
Date
Page
VLT-MAN-ESO-14650-4942
P96
24.06.2015
130 of 161
ESO, Karl-Schwarzschild-Str. 2, 85748 Garching bei München, Germany
Table
29:
User
defined
and
fixed
parameters
for
the
template
XSHOOTER_ifu_obs_FixedSkyOffset.
It allows to alternate object and sky observations taking
the sky at fixed postion.
XSHOOTER_slt_ifu_FixedSkyOffset
Keyword
Range
Default Value
Label in P2PP
Free parameters
DET1.WIN1.UIT1
0..36000
UVB exposure time (s)
DET1.READ.CLKDESCR
100k/1pt/hg
UVB readout mode
DET2.WIN1.UIT1
0..36000
VIS exposure time (s)
DET2.READ.CLKDESCR
100k/1pt/hg
VIS readout mode
DET3.DIT
0..36000
NIR Detector Integration
Time (s)
DET3.NDIT
1..20
1
number of DITs
SEQ.NEXP.UVB
0..100
1
UVB number of exposures
per offset position
SEQ.NEXP.VIS
0..100
1
VIS number of exposures per
offset position
SEQ.NEXP.NIR
0..100
1
NIR number of exposures
per offset position
SEQ.FIXOFF.RA
-100..100
0
RA fixed offset (“)
SEQ.FIXOFF.DEC
-100..100
0
DEC fixed offset (“)
SEQ.JITTER.WIDTH
0..2
0
Jitter box width in “
SEQ.NABCYCLES
0..100
1
Number OS or SO cycles
SEQ.OFFSET.ZERO
T, F
T
Return to Origin?
Fixed Values
INS.MODE
SLITSPEC,
IFUSPEC
IFUSPEC
Instrument Mode
INS.OPTI3.NAME
see Table 4
1x12.6
UVB slit
INS.OPTI4.NAME
see Table 7
1x12.6
VIS slit
INS.OPTI5.NAME
see Table 8
1x12.6
NIR slit
SEQ.AGSNAPSHOT
T, F
F
Take an acquisition image
before science exposures?