background image

3

EN

Dear customer,
You have purchased a high-quality technical 

device with which you will have years of sauna 

fun. This sauna heater was designed and inspect-

ed according to the current European safety 

standards and manufactured at the factory 

in accordance with the quality management 

standard DIN EN ISO 9001:2008.
This detailed installation and operation manual 

has been prepared for your information. Please 

in particular thoroughly read the 

important 

notes

 and the information on electrical con-

nection.
We wish you exhilarating recreational experience 

and lots of fun with your sauna!

Intended use

This sauna heater is exclusively intended for the 

heating of sauna cabins in combination with an 

appropriate control unit. 

Any other use over and above the intended 

purpose is not considered as appropriate use! 

Compliance of the standard operation, mainte-

nance and repair conditions is also an element 

of appropriate use.

The manufacturer cannot be held liable for 

deviating, unauthorized alterations and any re-

sulting damages: the initiator of these changes 

bears the full risk.

General information

Please check whether the unit has arrived in per-

fect condition. Any transport damages should be 

immediately reported to the freight forwarder 

delivering the goods or you should contact the 

company that shipped the goods. 

Please note that you will only be able to achieve 

an optimum sauna climate if the cabin with its air 

intake and ventilation, the sauna heater and the 

control unit are aligned to each other.

Please observe the information and stipulations 

made by your sauna supplier.

Sauna heaters heat up your sauna cabin using 

heated convective air. Here, fresh air is drawn 

in from the air intake which, when heated, rises 

upwards (convection) and is then circulated 

within the cabin. Part of the used air is pushed 

out through the vent in the cabin. This creates a 

typical  sauna climate which can achieve temper-

atures of approx. 110°C measured directly under 

the ceiling of your sauna, dropping in temper-

ature to approx. 30-40°C towards the floor. It is 

therefore not unusual to measure temperatures 

of 110°C on the temperature sensor hanging 

over the heater, whilst the thermometer hanging 

on the sauna wall, approx. 20-25 cm under the 

cabin ceiling, only indicates 85°C. The bathing 

temperature generally lies between 80°C and 

90°C in the area of the upper bench when the 

temperature is set to maximum.

Please note that the highest temperatures are 

always generated over the sauna heater and that 

the temperature sensor and the safety limiter 

must be mounted there in accordance with the 

control unit installation instructions.

When heating up for the first time, you may 

notice a slight  smell caused by evaporating 

lubricants used in production processes. Please 

ventilate your cabin before beginning your 

sauna bath.

Summary of Contents for THERMAT

Page 1: ...INNOVATIVE SAUNA TECH NOLOGY MADE IN GERMANY IP x4 THERMAT Sauna Heater print no 2934 4632 34 18 Installation and operation instruction EN...

Page 2: ...clearances 8 Mechanical installation and connections 8 9 Inner wiring 10 Connection example 400V 3N 10 Connection example 230V 1N 4 5 6 kW 11 Connection example 230V 1N 7 5 9 kW 12 Special advice for...

Page 3: ...shipped the goods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater and the control unit are aligned to each other Ple...

Page 4: ...in untreatedmaterials e g spruce Only a sauna heater with the appropriate power output may be installed in the sau na cabin Please provide air intake and vent open ings in each sauna cabin The air int...

Page 5: ...e cabin size in rela tion to the power input in kW When installing the sauna heater please ensure that the vertical clearance be tween the sauna heater upper edge and the sauna ceiling is maintained P...

Page 6: ...where the cable exits the sauna heater and guide this cable outside through the hole to the control unit The cable and all other connecting cables mains power cables and cabin lighting should be inst...

Page 7: ...on to 230V 1N AC power supply possible Power rating 4 5 kW 6 0 kW 7 5 kW 9 0 kW For sauna size 6 8 m 6 8 m 7 10 m 9 14 m Min size air inlet and exhaust vent 35 x 3 cm 35 x 4 cm 35 x 5 cm 35 x 6 cm Hei...

Page 8: ...g bracket over the air intake vent as shown in the Illust 2 3 and screw it onto cabin wall with the spax screws from the delivery scope Illust 2 Illust 3 Wall mounting bracket 64 cm 58 5 cm cabin wall...

Page 9: ...ver with spacer Illust 4 Terminal block Lock nut Cable gland Illust 5 3 Close the terminal box with cover using 2 fixation screws Observe that the integrated spacer faces outwards See Illust 4 for det...

Page 10: ...Hz 400 V 3 x 16 35 x 3 cm 5 x 2 5 mm 5 x 1 5 mm no Econ D series Emotec D series EmoStyle D series EmoTouch 6 0 kW 35 x 4 cm 7 5 kW 35 x 5 cm 9 0 kW 35 x 6 cm All cross sections of a line are minimum...

Page 11: ...se a proper fuse protection andsuitableconnectioncable Riskoffireanddamagestohardwarebyimproperconnection Power rating per DIN Electrical connection Fuse protection for control unit in A Connecting ca...

Page 12: ...nectioncable Riskoffireanddamagestohardwarebyimproperconnection Power rating per DIN Electrical connection Fuse protection for control unit in A Connecting cable mains control unit in mm Connecting ca...

Page 13: ...sauna control unit Risk of fire and damages to control unit and heater Do not just bridge the power input terminals L1 L2 L3 Mare sure to protect each input with an individual fuse Risk of fire and d...

Page 14: ...daily commercial use we recommend to check the condition of sauna stones every 2 3 months and to reshuffle them By home use the sauna stones need to be checked and reshuffled at least once per year N...

Page 15: ...other electrical units will be protected by this ELCB Under current manufacturing technology it is not reasonable to use heating elements for sau na heaters which do not collect moisture from the sur...

Page 16: ...your questions quickly and compe tently please provide the information printed on the type shield including the model item no and serial no in all inquiries Equipment commissioning date ______________...

Page 17: ...roducts is designed for the ship ping of individually packed goods pallet We expressly point out that our packaging is not suitable for individual shipments via parcel post The manufacturer shall acce...

Reviews: