EN-12
Installation and Operating Instructions - EOS Zeus HD / Zeus L HD
Identification
EN
Heater guard rail (optional)
A heater guard rail may be placed around the upper edge of the heater. It
prevents accidental contact with the hot heater.
2.4 Technical data
Electrical connection – lines
Electrical connection – fuse protection
Accessories (optional)
Item no.
Heater guard rail 270°
Abachi
94.6605
Walnut
94.6597
Heater guard rail 360°
Abachi
94.6606
Walnut
94.6598
Installation kit
94.6761
Sauna stones, grain size 100–150 mm,
total volume approx. 70–75 kg
Heater output
Electrical con-
nection
Connection
mains –
control unit
Connection
mains – power
extension unit
Connection
control unit –
heater
Connection
power exten-
sion unit –
heater
Connection
control unit –
power exten-
sion unit
20 kW
400 V 3N AC
50 Hz
5 x 2.5 mm
2
5 x 4 mm
2
5 x 1.5 mm
2
5 x 4 mm
2
4 x 1.5 mm
2
24 kW
5 x 4 mm
2
30 kW
3 x 1.5 mm
2
5 x 10 mm
2
-
2 x (5 x 6 mm
2
)
36 kW
3 x 1.5 mm
2
5 x 16 mm
2
2 x (5 x 6 mm
2
)
Heater
output
Fuse protection
for control unit
Fuse
Power extension
unit (LSG)
20 kW
3 x 16 A
3 x 25 A
24 kW
3 x 35 A
30 kW
1 x 16 A
3 x 50 A
36 kW
1 x 16 A
3 x 63 A