34
6.Troubleshooting
6.Troubleshooting
6.Troubleshooting
6.Troubleshooting
This chapter is designed to help the user identify and rectify basic faults or the results
of incorrect operation. When locating a fault, proceed in the order shown in the table.
Fault
Possible cause
Action
Truck does
not start.
– Battery connector not
connected
-
Key switch in “0” position
-
Battery charge too low
-
Faulty fuse
-
Truck in charge mode
– Check the battery connector and
connect if necessary.
– Set key switch to “I”
– Check battery charge, charge
battery if Necessary
– Test fuses
– Interrupt charging
Load can
not be
lifted
–
Charge capacity below 20%
/ 40%
–
Hydraulic oil level too low
–
Excessive load
–
Charging the battery
–
Check the hydraulic oil level
–
Note maximum capacity (see
data plate)
If the fault cannot be rectified after carrying out the remedial procedure, notify the
manufacturer ’ s service department ,as any further troubleshooting can only be
performed by specially trained and qualified service personnel.