73
Error Message
Possible cause
Fault elimination
Error
Error text
62
TH.
PROTECTION
The temperature of the controller
base plate is above 85 °C.
The maximum current is
proportionally decreased with the
temperature excess from 85 °C up
to 105 °C. At 105°C the current is
It is necessary to improve the
controller cooling. To realize an
adequate cooling in case of
finned heat sink important factors
are the air flux and the cooling-air
temperature. If the thermal
204
BRAKE RUN
OUT
The CPOT BRAKE input read by
the microcontroller is at its
maximum value without the
hand-brake request.
Check the mechanical calibration
and the functionality of the brake
potentiometer. If the alarm is still
present, replace the logic board.
0
Reload HM from
MDI
The hour-meter of the controller is
transferred and recorded on the
hour-meter of the standard MDI.
65
MOTOR
TEMPERAT.
This warning occurs when the
temperature sensor is open (if
digital) or if it has overtaken the
MAX MOTOR TEMP threshold (if
analog).
- Check the temperature read by
the thermal sensor inside the
motor through the MOTOR
TEMPERATURE reading in the
TESTER function.
- Check the sensor ohmic value
and the sensor wiring.
- If the sensor is OK, improve the