33
IMPORTANT: Servicing other than the procedures
described below should be performed only by an
authorized service representative.
Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical,
rst press the power switch
to the off position and unplug the power cord.
Wipe exterior parts of the elliptical with a damp cloth
and a few drops of mild dish soap. Then, wipe the
elliptical with a cloth dampened with clean water, and
dry the elliptical with a soft towel.
IMPORTANT: Do
not spray liquid directly onto the console or onto
other parts of the elliptical.
To avoid damage to the
console, keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If lines appear in the console display, see HOW TO
CHANGE CONSOLE SETTINGS on page 29 and
adjust the contrast level of the display.
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the
displayed heart rate appears to be too high or too low,
see step 5 on page 24.
HOW TO CALIBRATE THE RAMP
If the ramp is not functioning properly, the ramp may
need to be calibrated. To calibrate the ramp, press and
hold the User Defined button for several seconds until
the test mode appears in the display.
Press the User Defined button again. Then, press the
Ramp increase or decrease button to calibrate the
ramp. The ramp will move upward and downward as it
calibrates.
When the ramp stops moving, the ramp is calibrated.
Then, press the User Defined button repeatedly until
the last screen of the test mode appears. Then, press
the User Defined button to exit the calibration mode.
HOW TO ADJUST THE DRIVE BELT
If the pedals slip while you are pedaling, even while
the resistance is adjusted to the highest level, the drive
belt may need to be adjusted.
Press the power switch to the off position and
unplug the power cord.
To adjust the drive belt,
rst see assembly step 11 on
page 12. Remove the Right Roller Arm (45) from the
Right Pedal Arm (58).
Next, see EXPLODED DRAWING A on page 41 and
EXPLODED DRAWING B on page 42. Remove the
M8 x 16mm Screw (72), the Axle Cover (53), and the
M8 x 25mm Washer (149) from the upper end of the
Right Roller Arm (45). Then, remove the Right Roller
Arm from the right Crank Arm (20). Set the Right Roller
Arm out of the way.
Then, see assembly step 21 on page 16. Using a
at
screwdriver, release the tabs on the Shield Cover (75)
and slide it upward.
See EXPLODED DRAWING C on page 43. Remove
all the M4 x 16mm Screws (104) from the Right Front
Shield (74). Next, remove the M4 x 22mm Screw (127)
from the Left Front Shield (73).
Then, gently remove
the Right Front Shield.
Next, locate and loosen the Idler Screw (101). Tighten
the Belt Adjustment Screw (88) until the Drive Belt
(113) is tight. Then, retighten the Idler Screw.
Reattach the right front shield, the shield cover, and the
right roller arm.
MAINTENANCE AND TROUBLESHOOTING
101
88
113