Owner's Manual for EPILOG Legend Model 6000
December, 2000
4
Section 1 – Getting Started
CONNECTING POWER
Laser systems 50 watts and under: Requires a 100 to 240 VAC, single-phase electricity outlet. The Legend
will automatically adjust for the line voltage. The Legend should be provided with a dedicated 15-amp
circuit, which can be shared with the computer running the Legend. The 50 watt Legend will leave little
reserve power on a normal 15 amp 115 Volt service, and the computer may require a separate circuit.
Laser systems over 240 VAC, single phase electrical outlet. The electrical outlet should be fitted with a
NEMA L6-15R receptacle (HUBBEL 4560 or equivalent). If not already available, a licensed electrician
prior to the arrival of the Epilog installation technician must perform the proper circuit wiring.
The location of the power cord receptacle of the Legend is shown in the drawing below, and is located on the
left side of the machine near the back.
On/Off
Switch
Power Cord
Receptacle
Circuit
Breakers
On/Off
Switch
Power Cord
Receptacle
UNDER 50 WATTS
50 WATTS AND ABOVE
1)
Locate the “Power” label on the left side of the machine
, near the back. The label indicates the
required operating voltage range for the machine.
Please verify that the machine is the correct