Owner's Manual for EPILOG Legend Model 6000
December, 2000
76
Section 15 – Servicing the Legend
POWER SUPPLY
The power supply (part #LM2-600/2-1200/2-2400) is located in the power supply bay, see diagram on page
61. To remove and/or service this module, first turn the machine off and unplug the power cord from the
machine or from the wall. There are three versions of the power module. They have different capacities.
Standing at the rear of the machine, remove the plate on the lower right corner. It is held in place with
phillips head screws. Also remove the laser cover, which is the cover across the top of the cabinet, see
diagram on page 58. The laser cover has a connector that must be demated. Press on the tab to release it.
To remove the power module, loosen and remove the four phillips head screws on the outside of the machine
shown in the drawing below. Demate the two connectors shown in the drawing. Then loosen the two captive
screws across the top of the module. Remove one final screw located above and to the left of the bottom
connector. The power module can now be removed. Slide it towards the center of the machine and lift it
clear. Then install the replacement. Please remember to return the failed component to Epilog.
Captive Screw
(Two Places)
Phillips Screw
(Four Places)
Phillips Screw
(under power supply)
1200 WATT
2400 WATT
Connector
Connector
600 WATT