Rebuild or replace storage disks
To start a manual disk check:
1. Connect to the admin interface using your preferred connection mechanism. See
2. Login as admin.
3. Select the
Disk Check
link in the Configuration menu; the disk maintenance page opens.
4. Click the
Check Now
button; a new page opens showing you the progress of the disk check.
Do not interrupt power to the system during the disk check.
5. When the disk check is complete, the main page returns and a summary is shown.
6. If any unrecoverable errors are detected, contact Epiphan support.
Rebuild or replace storage disks
The rackmount Standalone VGA Grid can be optionally configured with storage configured in a RAID array.
Periodically you may wish to clean the RAID array to start from scratch, or you may want to introduce new
disks in place of the old ones.