background image

page | 5

© 2015 Episode®

CONNECT

CAUTION: 

All connections and switching must be done with the amplifier turned off. Connect the power cord 

last to ensure that the amplifier is off during all the connections and set up.

RCA Line Level

Use high-quality RCA cables that feature low impedance with adequate shielding and high-quality connectors.

Speaker Outputs

Use 14-18 gauge stranded two-conductor speaker wire. Connect the appropriate conductor to each screw terminal, 

observing correct polarity.

CAUTION: 

When two subwoofers are connected in parallel, the nominal impedance of each subwoofer should 

not be less than 8Ω. 

LS

RS

SUB

CEN

L

R

Switched 

Outlet

+ 12V Trigger

Out

OUT

IN

IN

R

L

(LFE)

OUT

TRIGGER

DC 12V

A

B

C

EQ

SETTINGS 

EQ

MODE 

BYPASS TRIGGER

AUTO

ON

ON

POWER MODES

50

300 (LFE)

0

180

0

10

100-120V AC

220-240V AC

FUSE T3.15AL/250V

EA-AMP-SUB-1D-150

100-120V~60Hz/220-240V~50Hz  150WATTS

CROSSOVER

PHASE

VOLUME

SUB 1

SUB 2

Designed and Engineered in USA

Made in China

Total Impedance

(Sub 1 + Sub 2) Minimum 4Ω

+

-

OUT

IN

IN

R

L

(LFE)

OUT

TRIGGER

DC 12V

A

B

C

EQ

SETTINGS 

EQ

MODE 

BYPASS TRIGGER

AUTO

ON

ON

POWER MODES

50

300 (LFE)

0

180

0

10

100-120V AC

220-240V AC

FUSE T3.15AL/250V

EA-AMP-SUB-1D-150

100-120V~60Hz/220-240V~50Hz  150WATTS

CROSSOVER

PHASE

VOLUME

SUB 1

SUB 2

Designed and Engineered in USA

Made in China

Total Impedance

(Sub 1 + Sub 2) Minimum 4Ω

+

-

+

-

EA-AMP-SUB-1D-150

AV Receiver

EA-AMP-SUB-1D-150

Single Sub Connections

Dual Sub Connections

8Ω Minimum

8Ω Minimum

4Ω Minimum

Left & Right

Preamp Out

or

LFE Sub Out

!

!

© 2015 Episode®

Summary of Contents for EA-AMP-SUB-1D-150

Page 1: ......

Page 2: ...d on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the ca...

Page 3: ...reset A 4dB optimized for enclosures 4 cu ft EQ Preset B 7dB optimized for enclosures 1 4 cu ft EQ Preset C 10dB optimized for enclosures 1 cu ft 6 EQ MODE ON EQ SETTINGS are enabled while CROSSOVER P...

Page 4: ...lated area that provides adequate cooling A minimum of 5 should be allowed for optimum performance EA AMP SUB 1D 150 Installation Rack mount ears may be removed if the unit will not be installed in a...

Page 5: ...Out OUT IN IN R L LFE OUT TRIGGER DC 12V A B C EQ SETTINGS EQ MODE BYPASS TRIGGER AUTO ON ON POWER MODES 50 300 LFE 0 180 0 10 100 120V AC 220 240V AC FUSE T3 15AL 250V EA AMP SUB 1D 150 100 120V 60Hz...

Page 6: ...or AV Receiver LS RS SUB CEN LF RF Switched Outlet 12V Trigger Out OUT IN IN R L LFE OUT TRIGGER DC 12V A B C EQ SETTINGS EQ MODE BYPASS TRIGGER AUTO ON ON POWER MODES 50 300 LFE 0 180 CROSSOVER PHASE...

Page 7: ...for enclosures 4 cu ft EQ PRESET B 7dB optimized for enclosures 1 to 4 cu ft EQ PRESET C 10dB optimized for enclosures 1 cu ft 3 Set the controls to positions that will enable tuning for maximum perf...

Page 8: ...onnections of the speaker wire at both the speaker and amplifier The level adjustment is turned down Slowly turn the dial to the right to raise the volume Hum or buzzing sound is heard Check RCA input...