background image

Pg. 13

©2014 Episode™

Pg. 12

©2014 Episode™

13. Application Diagram

See the examples of applications below.  These diagrams illustrate typical uses of the ECA-70AMP-2D  

amplifier.

13.1 Single Source with Stereo Output

Le

ft

(C

H

1)

R

ig

ht

(C

h

2)

LOOP OUT

OUTPUTS

CAUTION:

INPUTS

ON

115/230V

OUT

IN

AUTO

ON

POWER

MODE

LEVEL

0V 0V

70V

70V

OF

ONLY

TYPE.

ATTENTION:

CH1

CH2

CH2

CH2

CH1

CH1

CH2

CH1

OFF

MASTER

POWER

FUSE TYPE:

T4AL 250V

T8AL 250V

VOLTAGE

SWITCH

E330247

Ch 1 Loop Out

Left to CH 1

Right to CH 2

For 70v Subwoofers,

visit our website. For 

Subwoofer wiring 

recommendations, 

please call Tech 

Support.

13.2 Two Sources with Two Mono Output  Zones

Z

on

e

2

(C

H

2)

Z

on

e

1

(C

h

1)

LOOP OUT

OUTPUTS

CAUTION:

INPUTS

ON

115/230V

OUT

IN

AUTO

ON

POWER

MODE

LEVEL

0V 0V

70V

70V

OF

ONLY

TYPE.

ATTENTION:

CH1

CH2

CH2

CH2

CH1

CH1

CH2

CH1

OFF

MASTER

POWER

FUSE TYPE:

T4AL 250V

T8AL 250V

VOLTAGE

SWITCH

E330247

Source 1

(Unbalanced RCA)

Source 2

(Balanced Input)

From Automaton System

12V Trigger Output

LOOP OUT option 

for use with 

another amp.

LOOP OUT option 

for use with 

another amp.

ECA-70AMP-2D-150

ECA-70AMP-2D-300

ECA-70AMP-2D-500

Continuous Power 

Output (All Channels)

150w per channel @ 

70V

300w per channel @ 

70V

500w per channel @ 

70V

Inputs per Channel

1 unbalanced (set-screw) and 1 balanced (RCA)

Input Sensitivity

1V

Input Impedance

10KΩ (unbalanced); 20KΩ ( balanced)

AUTO ON  Sensitivity

2.5mV

12 Volt Trigger Input

4.5-12V DC; 10K Ω

12 Volt Trigger Output

12V DC; 10mA

T.H.D.

0.03%

S/N ratio

95db A-weighted

Frequency Response

50 Hz to 20KHz

Distortion

0.1% THD 20 Hz-20 kHz

Input Voltage

115V AC/230V AC

Fuse

115V AC

T4AL 250V

T8AL 250V

T10AL 250V

230V AC

T2.5AL 250V

T4AL 250V

T5AL 250V

Power Consumption

400 watts

800 watts

1200 watts

Dimensions (Inches)

17”W x 2.3”H x 11”D

Weight

7.8 lbs

8.1 lbs

8.4 lbs

Certification

Meets FCC Part 15, UL EN60065

14. Specifications

15. Dimensions

POWER

2

1

PROT

-20

-10

CLIP

-30

ECA-70AMP-2D-300A

19.00in.

17.40in.

1.75in. 2.30in.

11.00in.

POWER

2

1

PROT

-20

-10

CLIP

-30

ECA-70AMP-2D-300A

19.00in.

17.40in.

1.75in. 2.30in.

11.00in.

Summary of Contents for ECA-70AMP-2D-150A

Page 1: ...Pg 1 2014 Episode Installation Manual 2 Channel 70 Volt Power Amplifiers ECA 70AMP 2D 150A ECA 70AMP 2D 300A ECA 70AMP 2D 500A ...

Page 2: ...e risque d incendie ou un choc électrique ne pas exposer cet appareil à la pluie ou à l humidité 1 Lisez ces instructions 2 Conservez ces instructions 3 Respectez tous les avertissements 4 Suivez toutes les instructions 5 Ne pas utiliser cet appareil près de l eau 6 Nettoyer avec un chiffon sec 7 Ne pas bloquer les ouvertures de ventilation Installer conformément aux instructions du fabricant 8 Ne...

Page 3: ...iring two separate channels for stereo audio or two zones of audio requiring different sources or levels With low heat output thanks to digital amplification and massive power output in a small 1U package these amplifiers are guaranteed to perform 1U Rack Height Save space in already crowded rack with the first 1U sized 70 volt amplifier on the market Digital 70 Volt Amplification State of the art...

Page 4: ...issue with installation or setup 3 Output Level Meter Level meter flashes green to indicate current output level for each channel LEDs will illuminate green accordingly as levels ranging from 30dB to 10dB are played If a channel is clipping the red CLIP LED will illuminate during periods of clipping turn down input level immediately if clipping occurs 6 Front Panel 7 Rear Panel Note ECA 70AMP 2D 3...

Page 5: ... Set Screw Connectors 1 Strip the outer jacket of the cable if applicable back about 2 and then strip the insulation of each wire back to expose the bare copper 2 Loosen the set screws on the connector using a 1 8 flat blade screwdriver 3 Twist the copper strands in conductor each clockwise insert them into the correct holes and tighten the screws Do not allow any strands of copper to touch and ca...

Page 6: ... volume control level if applicable for the best sounding and most reliable installation 1 Connect all speaker and audio source wiring and configure the amplifier Connect power to the amplifier but leave it turned Off at the Master Power Switch 2 If applicable Set all volume controls to their maximum volume setting 3 Set the LEVEL for each zone in use to baseline by turning the knob counterclockwi...

Page 7: ...rce 2 Balanced Input From Automaton System 12V Trigger Output LOOP OUT option for use with another amp LOOP OUT option for use with another amp ECA 70AMP 2D 150 ECA 70AMP 2D 300 ECA 70AMP 2D 500 Continuous Power Output All Channels 150w per channel 70V 300w per channel 70V 500w per channel 70V Inputs per Channel 1 unbalanced set screw and 1 balanced RCA Input Sensitivity 1V Input Impedance 10KΩ un...

Page 8: ... volume controls and test output with one speaker on known good wire run Verify correct source operation and input wiring Turn volume in source up to an audible level Is Power LED red If so see section above POWER LED is RED No sound from microphone input Set the phantom power switch to the correct mode for micro phone Verify with microphone manufacturer CLIP LED illuminates some or all of the tim...

Page 9: ...Pg 16 2014 Episode Rev 140417 1430 ...

Reviews: