background image

 

CDMA FWT SXT-2180 

5

 

            Technical Manual 

. Hidden Menu

 

 
*Note: User MUST input the security lock code when accessing below menu options. 

 

Emergency 

‘##01’ 

- In the Emergency Menu state, you can store 3-address. 
- Press 1~3 key to select an address slot, and then wait until you have heard a security tone. It likes as short melody. 
- Enter the security lock code, and press desired Emergency Number and then press ‘

À

’ to save. 

- If you press ‘#’ to release. 
   
Ex) ‘##011911*’ – Store number ‘911’ to 1st Emergency Slot. 

 

HOT Line 

‘##02’ 

- In the Hotline Menu state, you can store 1 address. 
- To set up the hotline, you should follow two steps 

  1. Set a hotline number which will be dialed automatically whenever you pick up the handset. 
  2. Set a hotline time to delay between picking up handset and dialing a hotline number. 

- After heard confirmation tone for a lock code, You can set a Hotline number. 
- And then press 

À

 to store it in a memory for preserving it on power-on/off cycle. 

- If you press ‘#’ instead of 

À

, it will be released. 

- And then if you stored a hotline number by pressing

À

, you should select hotline delay time from 1sec. to 9sec. Just 

press one key from 1 to 9 please. 
- And then press 

À

 to store your selection. 

- If you didn’t select the delay time, it will be set up default time on 2sec. 
 
Ex) ##02 

Î

 enter lock code 

Î

 39 

À

 + confirm tone 

Î

 4 + 

À

 

- This example shows you a hotline number was saved with the number are “39533447” and delayed time is 4 secs. 

 

A Key 

‘##04’ 

- In the A Key menu, you can make sure that whether A key is valid or not. 
- Input 26 digits of the A key what you want to valid. 
- After finished input, press ‘

À

’. 

- If the A key was valid, you can hear confirmation tone, but otherwise, you can hear an alert tone. 
 
Ex) 
##04 

Î

 26 digits (20 6 digits checksum) 

Î

 

À

 

 

Master Clear 

‘##05’ 

- In the Master clear mode, you can reset all setting value in Terminal. 
- When it was done, the Terminal is set to Factory initiate. 
 
NOTE: It will be erased all user data like as alarm, dial tone, etc. 
Ex) 
##05 

Î

 

À

 (Master Clear) 

 

Test Call ( will be used in a lab like CDG2 ) 

‘##06’ 

- In the Test call mode, you can. 

NEW 8K MARKOV 

SO55 LOOP BACK 

NEW 13K MARKOV 

 

 

3 8K 

LOOP 

BACK 

   

4 13K 

LOOP 

BACK 

   

5 SO54 

MARKOV 

   

-

 Pressing 

À

’ needs for make completed. 

 
Ex) 
##06 

Æ

 1~ 6 

Æ

 ‘

À

’ (Test call) 

 

Power Down Registration ( will be used in a lab like 
CDG2 ) 

‘##07’

- In this menu support the testing of the power down registration, 
  When it was done, the Terminal will be going to the power down mode   

and send the message of the power down registration. 

 
Ex) 
##07 

Î

 (Just press to this key to go for entering the power down) 

 
 

Summary of Contents for SXT-4080

Page 1: ...CDMA FWT SXT 2180 1 Technical Manual SXT 4080 CDMA 1XRTT FIXED WIRELESS TERMINAL 800 MHz CDMA TECHNICAL MANUAL VOICE COMMUNICATION and PCO PTB Application...

Page 2: ...d EPIVALLEY Corporation for the title to and use of the Product BY RETAINING AND USING THE PRODUCT AFTER RECEIPT OF IT YOU AGREE TO THE TERMS AND CONDITIONS INCLUDING WARRANTY DISCLAIMERS LIMITATIONS...

Page 3: ...ont of the will turn ON The following table describes the modes and operations of the indicator Status LED Don t care Section LED Description RSSI BATT Color Blink Color Blink 1 Power ON Green X None...

Page 4: ...tone indicates that no cellular service is available At that time you can check the RSSI status The LED of RSSI will be blink with red color Outgoing Call Restriction A slower beeping is an indicatio...

Page 5: ...press to store your selection If you didn t select the delay time it will be set up default time on 2sec Ex 02 enter lock code 39533447 confirm tone 4 This example shows you a hotline number was saved...

Page 6: ...up and press 2 to down When you determine the volume press to save but if you press don t save the volume value and exit DTMF 13 In the DTMF menu you can select DTMF tone length Press to long press t...

Page 7: ...don t want to set a caller ID press then release Caller ID types 1 BELLCORE 2 V 23 3 DTMF 4 None CID same as key Dial Tone 22 In the Dial tone menu you can select a dial tone for your country There ar...

Page 8: ...0 to 999 ms default 100 ms If entered time is out of ranges it will be ignored And if entered time is more than the on hook time it will be ignored as well You can not set a flash time bigger than on...

Page 9: ...nd a FWT will be reset Press to cancel what you did Voice privacy 44 You can set the option of Voice privacy to protect your voice from tapping But It is possible only an operator supports this featur...

Page 10: ...e following steps 1 Call 1st party 2 While in a call with 1st party dial a number of the 2nd party 3 Press hook switch or flash button 4 When it connected to 2nd party press hook switch or flash butto...

Page 11: ...RY ITEM SHOTKEY FUNCTION General 01 ESN 01 Electronic Serial Number 0101 Read Only Press or then Confirmation tone is heard Go to main state CAI Ver 02 Common Air Interface 0102 Read Only Press or the...

Page 12: ...r save Press go to main state ACCOLC 05 ACCess OverLoad Class 0 15 0305 Edit as 0 9 Press go to main state after save Press go to main state SETTING CHANNEL 06 Primary CH System A 01 030601 Edit as 0...

Page 13: ...6 030726 Home SID14 27 030727 Home NID14 28 030728 Home SID15 29 030729 Home NID15 30 030730 Home SID16 31 030731 Home NID16 32 030732 Home SID17 33 030733 Home NID17 34 030734 Home SID18 35 030735 Ho...

Page 14: ...0 20 030820 LOCK Home SID11 21 030821 LOCK Home NID11 22 030822 LOCK Home SID12 23 030823 LOCK Home NID12 24 030824 LOCK Home SID13 25 030825 LOCK Home NID13 26 030826 LOCK Home SID14 27 030827 LOCK H...

Page 15: ...E 11 0311 Edit as 1 2 Press 1 enable Press 2 disable Press go to main state after save Press go to main state MOB_TERM_HOME 12 0312 Edit as 1 2 Press 1 enable Press 2 disable Press go to main state af...

Page 16: ...its corresponding circuit breaker are functioning properly Battery Backup Failure If you re using the battery the unit must be connected to AC power for at least ___hours to fully charge the battery...

Page 17: ...device must accept ant interference received including interference that may cause undesirable operation Information to User This equipment has been tested and found to comply with the limits for a C...

Page 18: ...motor vehicles Check with the manufacturer or its representative to determine if these systems are adequately shielded from external RF energy You should also check with the manufacturer of any equipm...

Reviews: