Stand 26.11.08, SB 55 SV, Drills
Page 29 of 37
6
Failures
Attention!
Observe during abatement of failures the safety regulations. Therefore see chapter
Fehler! Verweisquelle konnte nicht gefunden werden., Fehler! Verweisquelle konnte
nicht gefunden werden., Fehler! Verweisquelle konnte nicht gefunden werden. und
5
.
6.1 Fault correction
Failure
Possible cause
Corrective measure
Motor does not
run
Current supply broken
Insert machine
Replace safety
Main switch defect
Replace switch
Reversing switch in position
<0>
Adjust turning direction
Reversing switch defect
Replace switch
Belt cover open
Cloce belt cover
Depth Stop
effectless
Depth Stop adjusted false
Adjust arrester
Depth Stop declamped
Arrest arrester
Centre sleeve
turns into false
direction
Reversing switch connected
false
Adjust turning direction
correct
Drill becomes
too hot
Adjusted false speed
Abate speed
Hole is not round Drill grinded false
Grind new and correct
Drill bent / damaged
Renew drill
Drill cants
Pressure at centre sleeve too
high
Abate pressure
Drill chuck does
not catch into
adaptor
Drill chuck / collet
contaminated or oiled
Clean collet and drill chuck
Summary of Contents for SB 55 SV
Page 30: ...Stand 26 11 08 SB 55 SV Drills Page 30 of 37 7 Exploded drawing 7 1 Exploded drawing actuator ...
Page 32: ...Stand 26 11 08 SB 55 SV Drills Page 32 of 37 9 Exploded drawing 9 1 Exploded drawing stand ...