26.01.07, SBS 32, Drills
Page 20 from 33
3.4
Positioning and assembly
3.4.1 Claims to installation location
The machine may not be in an explosive area. The machine is therefore
not construed. The acceptable environmental conditions have to be
followed at the installation location. Organise the installation location
according to the safety regulations for the use of this machine. See that
the installation location is not limited for the use, attendance and
maintenance.
Guarantee a boundless and free amenability of the mains plug and all
operation unit of the machine.
3.4.2 Assembly
Install the stand
Install the column in the stand and screw both parts
Lay in the gear rack into the table adjustment
Impose on the beam with gear rack about the column
Mount the end ring of the gear rack at the column
Mount the table and adjust it
Mount the head at the column and screw both parts
Mount the chip protection at the centre sleeve
3.4.3 Anchor - free assembly
Attention!
An anchor
– free positioning is not allowed because of safety causes
and therefore it is forbidden!
3.4.4 Anchor free assembly
Observe that the machine is anchored safe and correctly. Assure that you respect
the internal safety regulations.
Attract the anchor screws across balanced and not too feast, to avoid a break of
the stand. Adjust the machine perpendicular.
3.4.5 Positioning
See that the bottom/ ceiling at the installation location are stable enough. If the
rigidity is not enough, it can come to oscillation between machine and ground.
This can lead to failures at the machine or at the adjoining equipment.
See during positioning of the machine that the working place is designed
ergonomic.
Observe during position the machine the accident prevention regulations for your
business. The use, attendance and maintenance may not be limited. Bethink: A