background image

Installing Batteries 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

1. 

Open the battery door on the back of the meter by pushing the tab in the direction of the 

arrow and pulling the door up. 

2. 

Insert two batteries. You will hear opening music. 

3.

 

Put the battery door back in place and snap it closed. 

 

Summary of Contents for EasyMax Voice III

Page 1: ...1 EasyMax Voice III Self Monitoring Blood Glucose System Quick Reference Guide...

Page 2: ...pen the battery door on the back of the meter by pushing the tab in the direction of the arrow and pulling the door up 2 Insert two batteries You will hear opening music 3 Put the battery door back in...

Page 3: ...on to select ES En English ES Espa ol 2 And press power button to confirm the setting 3 Repeat step 1 and 2 to set the volume 1 The priority language of the blood glucose meter is set in English 2 The...

Page 4: ...te in your meter is important if you intend to use the meter memory 1 Press M button and C button to set the year Press power button to confirm the setting 2 Repeat step 1 to set the date 3 Repeat ste...

Page 5: ...a flat surface like a table 4 Remove the control solution bottle cap and wipe the tip of the bottle with a tissue 5 Squeeze the bottle until a tiny drop forms at the tip of the bottle 2 The meter turn...

Page 6: ...within the range printed on the test strip bottle 9 Press power button to repeat the test result Or you can also press C button or M button to set the volume before repeating the result 10 Remove the...

Page 7: ...The Lancing Device You must first load the lancet into the lancing device to get it ready for use 1 Unscrew the Cap 2 Insert the lancet into the lancing device firmly then twist off the protective co...

Page 8: ...average and 4 5 for thick or calloused skin 6 Set the lancing device aside until later in the test 5 Pull on the sliding barrel of the lancing device until it clicks and then release Now the lancing d...

Page 9: ...ing 3 When the blood drop flashes on the display the meter will tell the instruction Running A Blood Glucose Test With Blood From Your Fingertip 1 Wash your hands with soap and warm water Rinse and dr...

Page 10: ...indow Otherwise an inaccurate reading may result 7 The meter starts to count down from 5 seconds and speaks the result 8 Press power button to repeat the test result Or you can also press C button or...

Page 11: ...ble tip against the forearm 3 Press the trigger button to activate the lancing device Hold the device against forearm and increase pressure until the blood sample size is sufficient Running A Blood Gl...

Page 12: ...he cap 3 Pointing the lancing device toward a container for sharp or biohazard material slide the ejection button down to release the covered lancet into the container 2 Without touching the used lanc...

Page 13: ...individual test result 4 To delete a test result press C button for more than 3 seconds and display shows dEL Then press power button to confirm the deletion 5 Press C button to keep reviewing the re...

Page 14: ...n error message If you have any concerns please contact your local dealer Humidified Used strips Action Replace with a new strip Low power Action Replace with new batteries System fault Action Replace...

Page 15: ...still the same try a control solution test and if the control solution test falls within the correct range please contact your healthcare professional The test result is lower than 1 1 mmol L 20 mg d...

Page 16: ...test continues Action Relocate the meter to a location with temperature between 10 C 40 C 50 F 104 F The Lt and thermometer icon appears Temperature is too low outside the required range of 10 C 40 C...

Page 17: ...mail info epsbio com tw Website http www epsbio com tw 0537 Reference American Diabetes Association Standards of Medical Care for Patients with Diabetes Mellitus Diabetes Care 25 2002 p S37 Obelis s...

Reviews: