Page 9
EPS Stromversorgung GmbH
Alter Postweg 101 • 86159 Augsburg
Germany
Fon: +49 821 / 570451-0
Fax: +49 821 / 570451-25
ELR 9000 Series
1.7.5 Alarm signals
The equipment offers various possibilities for signalling alarm conditions, however, not for danger situations. The
signals may be optical (on the display as text) acoustic (piezo buzzer) or electronic (pin/status output of an analog
interface). All alarms will cause the device to switch off the DC input.
The meaning of the signals is as follows:
Signal
OT
(OverTemperature)
•
Overheating of the device
•
DC input will be switched off
•
Non-critical
Signal
OVP
(OverVoltage)
•
Overvoltage shutdown of the DC input occurs due to high voltage entering the device
•
Critical! The device and/or the load could be damaged
Signal
OCP
(OverCurrent)
•
Shutdown of the DC input due to excess of the preset limit
•
Non-critical, protects the source from excessive current drain
Signal
OPP
(OverPower)
•
Shutdown of the DC input due to excess of the preset limit
•
Non-critical, protects the source from excessive power drain
Signal
PF
(Power Fail)
•
DC input shutdown due to AC undervoltage or defect in the AC input
•
Critical on overvoltage! AC mains input circuit could be damaged
1.8
Technical data
1.8.1 Approved operating conditions
•
Use only inside dry buildings
•
Ambient temperature 0-50 °C
•
Operational altitude: max. 2000 m above sea level
•
Max 80% RH up to 30 °C, linear decrease to 50% RH at 50 °C
1.8.2 General technical data
Display:
Colour TFT touch screen with gorilla glass, 4.3”, 480pt x 272pt, capacitive
Controls:
2 rotary knobs with pushbutton functions, 1 button
The nominal values for the device determine the maximum adjustable ranges.