Operating Guide
PSI 8000 2U Series
Date: 28-06-2012
Using the power supply
6.15.6 Display during the function run
Also see the overview on the previous page.
70.00 V
35.00 A
1400kW
Display of the actual values
On the left side of the display the actual values are shown in
small font. The status of the active control (CV/CC/CP) is dis-
played to the right of the corresponding value.
20.00 V
15.00 A
1500kW
The set values of the sequence point, which will
be reached after the sequence has been processed, are shown
on the right side of the display
1
2/5
2
Status display of the function run. The remaining
repetitions of the function (1) and of the sequence (2), as well as
the current sequence (2/_) and the momentarily active sequence
point (_/5) are displayed.
Function manager is halted or wasn’t started yet
Function manager is running
15:05 m
The elapsed time since the function gene-
rator was started is also displayed. The time display is stopped
when the function manager stops. The
STEP
,
RUN
or
GO
keys
are used to run the function manager in several ways. The time
display will then continue to count.
{ON,OFF}
State of the power output
Besides the state of the power output an alarm, a warning or a
signal can be displayed.
6.15.7 Controlling the function manager
The interactive control panel provides keys to control the func-
tion manager. You can halt, continue, reset it to the starting point
or exit the function by using these keys.
Before the function manager is really setting the power supply
you can simulate the function on the display. During this
- the output is not switched on and
- the sequence points are processed step by step and can be
verified this way.
The execution is also controllable via communication with an
interface card. Here you can additionally set one stop point at
one of the 50 sequence points. This sequence point is processed
and the sequence/function is then halted.
The
ESC
button exits the function manager and returns
to the former state of the power supply.
The
STEP
button is used to run a sequence stepwise.
The current sequence point is excuted after the button was
pressed. After the „step“ has been executed, the set values,
which are displayed in upper right corner of the display, are set.
The
RUN
button starts the function manager and the
function is run as it was defined. The sequence points are then
processed consecutively.
Example for a simulation during standby:
Use the
GO
button to continue the function after it was
stopped.
Alternatively, you can reset the function manager to the
start of the current function with the
NEW
button.