PSI 9000 3U Series
Fon: +49 821 / 570451-0
Fax: +49 821 / 570451-25
1.8.3
Specific technical data
(1 Related to the nominal values, the accuracy defines the maximum deviation between an adjusted values and the true (actual) value.
Example: a 80 V model has min. 0.1% voltage accuracy, that is 80 mV. When adjusting the voltage to 5 V, the actual value is allowed to differ max. 80 mV, which
means it might be between 4.92 V and 5.08 V.
(2 RMS value: LF 0...300 kHz, PP value: HF 0...20MHz
(3 Typical value at 100% output voltage and 100% power
(4 The display error adds to the error of the related actual value on the DC output
3.3 kW / 5 kW
Model 3U
PSI 9040-170 PSI 9080-170 PSI 9200-70
PSI 9360-40
PSI 9500-30
AC Input
Input voltage
340...460 V AC 340...460 V AC 340...460 V AC 340...460 V AC 340...460 V AC
Input connection
2ph,PE
2ph,PE
2ph,PE
2ph,PE
2ph,PE
Input frequency
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
Input fuse (internal)
2x T16 A
2x T16 A
2x T16 A
2x T16 A
2x T16 A
Leak current
< 3.5 mA
< 3.5 mA
< 3.5 mA
< 3.5 mA
< 3.5 mA
Power factor
> 0.99
> 0.99
> 0.99
> 0.99
> 0.99
DC Output
Max. output voltage U
Max
40 V
80 V
200 V
360 V
500 V
Max. output current I
Max
170 A
170 A
70 A
40 A
30 A
Max. output power P
Max
3.3 kW
5 kW
5 kW
5 kW
5 kW
Overvoltage protection range
0...44 V
0...88 V
0...220 V
0...396 V
0...550 V
Overcurrent protection range
0...187 A
0...187 A
0...77 A
0...44 A
0...33 A
Overpower protection range
0…3.63 kW
0…5.50 kW
0…5.50 kW
0…5.50 kW
0…5.50 kW
Temperature coefficient for set
values Δ/K
Voltage / current: 100 ppm
Voltage regulation
Adjustment range
0...40 V
0...80 V
0...200 V
0...360 V
0...500 V
Accuracy
(1
(at 23 ± 5°C)
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
Stability at ±10% ΔU
AC
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
Stability at 0...100% load
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
Rise time 10...90% ΔU
Max. 15 ms
Max. 15 ms
Max. 15 ms
Max. 15 ms
Max. 15 ms
Display: Resolution
See section
„1.9.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤ 0.2% U
Max
≤ 0.2% U
Max
≤ 0.2% U
Max
≤ 0.2% U
Max
≤ 0.2% U
Max
Ripple
(2
< 200 mV
PP
< 16 mV
RMS
< 200 mV
PP
< 16 mV
RMS
< 300 mV
PP
< 40 mV
RMS
< 320 mV
PP
< 55 mV
RMS
< 350 mV
PP
< 70 mV
RMS
Remote sensing compensation
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Fall time at no load after switching
DC output off
-
Down from 100% to <60 V: less than 10 s
Current regulation
Adjustment range
0...170 A
0...170 A
0...70 A
0...40 A
0...30 A
Accuracy
(1
(at 23 ± 5°C)
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
Stability at ±10% ΔU
AC
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
Stability at 0...100% ΔU
OUT
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
Ripple
(2
< 80 mA
RMS
< 80 mA
RMS
< 22 mA
RMS
< 18 mA
RMS
< 16 mA
RMS
Display: Resolution
See section
„1.9.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤ 0.2% I
Max
≤ 0.2% I
Max
≤ 0.2% I
Max
≤ 0.2% I
Max
≤ 0.2% I
Max
Compensation 10%->90% load
< 1.5 ms
< 1.5 ms
< 1.5 ms
< 1.5 ms
< 1.5 ms
Power regulation
Adjustment range
0…3.30 kW
0…5.00 kW
0…5.00 kW
0…5.00 kW
0…5.00 kW
Accuracy
(1
(at 23 ± 5°C)
< 1% P
Max
< 1% P
Max
< 1% P
Max
< 1% P
Max
< 1% P
Max
Stability at ±10% ΔU
AC
< 0.05% P
Max
< 0.05% P
Max
< 0.05% P
Max
< 0.05% P
Max
< 0.05% P
Max
Stability at 10-90% ΔU
OUT
* ΔI
OUT
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max
Display: Resolution
See section
„1.9.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤ 0.75% P
Max
≤ 0.8% P
Max
≤ 0.8% P
Max
≤ 0.8% P
Max
≤ 0.8% P
Max
Efficiency
(3
~ 93%
~ 93%
~ 95%
~ 95%
~ 95,5%