4
9 –Solar Module Terminals
Connect solar modules.
10 –Battery Terminals
Connect batteries.
11 –Load Terminals
Connect loads.
3 Installation Instructions
3.1 General Installation Notes
Read through the entire installation section first before beginning
installation.
Be very careful when working with batteries. Wear eye protection. Have
fresh water available to wash and clean any contact with battery acid.
Uses insulated tools and avoid placing metal objects near the batteries.
Explosive battery gasses may be present during charging. Be certain there
is sufficient ventilation to release the gasses.
Avoid direct sunlight for outdoor use.
Loose power connections and/or corroded wires may result in resistive
connections that melt wire insulation, burn surrounding materials, or even
cause fire. Ensure tight connections and use cable clamps to secure cables
and prevent them from swaying in mobile applications.
Use with Gel, Sealed or Flooded batteries only.
Battery connection may be wired to one battery or a bank of batteries. The
following instructions refer to a singular battery, but it is implied that the
battery connection can be made to either one battery or a group of
batteries in a battery bank.
Select the system cables according to 3.5A/mm
2
current density
3.2 Mounting
NOTE: When mounting the controller, ensure free air
through the controller heat sink fins. There should be at
least 6 inches (150 mm) of clearance above and below the
controller to allow for cooling. If mounted in an
enclosure, ventilation is highly recommended.