4.2.13 Waste Toner Full Sensor Removal
1. Remove the Front Cover. (See “Front Cover Removal” on page -142.)
2. Remove the Operation Panel. (See “Operation Panel Removal” on
page -143.)
3. Remove the Front Inner Cover. (See “Front Inner Cover Removal” on
page -143.)
4. Disconnect the harness for the Waste Toner Full Sensor from the
connector.
5. Remove the Waste Toner Full Sensor.
Figure 4-33. Waste Toner Full Sensor Removal