EPSON AcuLaser C2000 / AcuLaser C1000
Revision E
Disassembly and Assembly
Disassembling Procedure
173
4.2.22.3 Belt Cleaner Estrangement Position Sensor
Removal
1. Remove the Left Frame Plate. (See “Left Frame Plate Removal” on
page -172.)
2. Release the hook of the belt cleaner estrangement position sensor.
Figure 4-60. Belt Cleaner Estrangement Position Sensor Removal
4.2.22.4 PWB-I (Belt Cleaner Control Board) Removal
1. Remove the Left Frame Plate. (See “Left Frame Plate Removal” on
page -172.)
2. Remove 4 screws securing the PWB-I (Belt Cleaner Control Board).
Figure 4-61. PWB-I (Belt Cleaner Control Board) Removal