C8 Maintenance 14. Replacing the M/C Cable
C Series Maintenance Manual Rev.2
405
14. Replacing the M/C Cable
Each motor is fed power by the battery for backup. Therefore, position data is held even
after turning OFF the Controller. The position data will be lost when the cable connector
connected to the battery is disconnected. And the EPSON RC+ will display the error
message of encoder alarm occurrence when the Controller is turned ON.
WARNING
■
Do not connect or disconnect the motor connectors while the power to the robot
system is turned ON. Connecting or disconnecting the motor connectors with
the power ON is extremely hazardous and may result in serious bodily injury as
the Manipulator may move abnormally, and also may result in electric shock
and/or malfunction of the robot system.
■
To shut off power to the robot system, disconnect the power plug from the power
source. Be sure to connect the AC power cable to a power receptacle.
DO NOT connect it directly to a factory power source.
■
Before performing any replacement procedure, turn OFF the Controller and
related equipment, and then disconnect the power plug from the power source.
Performing any replacement procedure with the power ON is extremely hazardous
and may result in electric shock and/or malfunction of the robot system.
CAUTION
■
When disconnecting the connectors during the replacement of the cable unit, be
sure to reconnect the connectors to their proper positions. Improper connection
of the connectors may result in improper function of the robot system.
For details on the connections, please contact the supplier of your region.
■
When installing the cover, be careful not to allow the cables to interfere with the
cover mounting and do not bend these cables forcibly to push them into the cover.
Unnecessary strain on cables may result in damage to the cables, disconnection,
and/or contact failure. These are extremely hazardous and may result in electric
shock and/or improper function of the robot system. When routing the cables,
check the cable locations after removing the cover. Be sure to place the cables
back to their original locations.
■
Be sure to connect the cables properly. Do not allow unnecessary strain on the
cables. (Do not put heavy objects on the cables. Do not bend or pull the cables
forcibly.) Unnecessary strain on cables may result in damage to the cables,
disconnection, and/or contact failure. These are extremely hazardous and may
result in electric shock and/or improper function of the robot system.
M/C cable
(Figure: C8-A1401** (C8XL))
Summary of Contents for C Series
Page 1: ...Rev 2 EM221R5039F 6 Axis Robots C series Maintenance Manual ...
Page 2: ...Manipulator manual C4 series Maintenance Manual Rev 2 ...
Page 20: ...Table of Contents xviii C Series Maintenance Manual Rev 2 ...
Page 22: ......
Page 69: ...C4 Maintenance 4 Cable Unit C Series Maintenance Manual Rev 2 49 ...
Page 70: ...C4 Maintenance 4 Cable Unit 50 C Series Maintenance Manual Rev 2 ...
Page 72: ...C4 Maintenance 4 Cable Unit 52 C Series Maintenance Manual Rev 2 ...
Page 73: ...C4 Maintenance 4 Cable Unit C Series Maintenance Manual Rev 2 53 ...
Page 74: ...C4 Maintenance 4 Cable Unit 54 C Series Maintenance Manual Rev 2 4 2 2 Power Cable ...
Page 75: ...C4 Maintenance 4 Cable Unit C Series Maintenance Manual Rev 2 55 ...
Page 196: ......
Page 283: ...C8 Maintenance 4 Cable Unit C Series Maintenance Manual Rev 2 263 ...
Page 284: ...C8 Maintenance 4 Cable Unit 264 C Series Maintenance Manual Rev 2 ...
Page 286: ...C8 Maintenance 4 Cable Unit 266 C Series Maintenance Manual Rev 2 C8 A1401 C8XL ...
Page 442: ...C8 Maintenance 18 C8 Option Parts List 422 C Series Maintenance Manual Rev 2 ...
Page 444: ......
Page 516: ...C12 Maintenance 4 Cable Unit 496 C Series Maintenance Manual Rev 2 ...
Page 517: ...C12 Maintenance 4 Cable Unit C Series Maintenance Manual Rev 2 497 ...
Page 518: ...C12 Maintenance 4 Cable Unit 498 C Series Maintenance Manual Rev 2 4 2 2 Power Cable ...
Page 519: ...C12 Maintenance 4 Cable Unit C Series Maintenance Manual Rev 2 499 ...