Maintenance 4. Cable Unit
C12 Rev.3
139
Installation: Cable unit (M/C cable downward)
1.
Perform the installation steps (1) to (62) of
Maintenance: 4.1.1 Replacing the Cable Unit (M/C Cable Backward)
.
2.
Turn the Manipulator laterally.
CAUTION
■
When turning the Manipulator laterally, there must be two or more people to work
on it so that at least one of them can support the arm while the others are removing
the bolts.
Removing the bolts without supporting the arm may result in the arm falling, bodily
injury, and/or malfunction of the robot system.
3.
Install the brake power supply to the plate.
The cables should be located in the direction as shown in the photo.
(See the photo.)
Cross recessed head screws with washer: 2-M3
×
6
Tightening torque: 0.45
±
0.1N·m
4.
Install the ground wire terminals to the plate.
Cross recessed head screws with washer:
: 9-M4
×
8, 2-M3
×
6
Tightening torque : 0.9
±
0.1N·m (M4
×
8)
0.45
±
0.1 N·m (M3
×
6)
5.
Install the following connectors according to the marks on the connector plate.
RJ45 connector: Ether
F-sensor connector: F-sensor
6.
Connect the M/C cable connectors.
Connectors: X11, X12, X14, BR010, BR011, X010, X020, X040, LED, GS01, BT1
7.
Install the D-sub connectors according to the marks on the connector plate.
Left: D-sub connector for brake release (with a wire marker: SW1): B-release
Right: D-sub connector for user wiring (without a wire marker: With round terminal): D-sub
Summary of Contents for C12 Series
Page 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C12 series Rev 3 ...
Page 8: ...vi C12 Rev 3 ...
Page 14: ...Table of Contents xii C12 Rev 3 ...
Page 16: ......
Page 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Page 84: ......
Page 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Page 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Page 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...