Maintenance 8. Joint #4
238
C12 Rev.3
4.
Remove the Arm #3 cable bracket and cable protection sheet.
Hexagon socket head cap bolts: 2-M3
×
6
The Arm #3 cable bracket and cable protection sheet will be used
again. Be careful not to lose them.
5.
Remove the Arm #4 side cover.
For details, refer to
Maintenance: 3 Covers.
6.
Remove the cable protection plate attached to the Arm #4.
Hexagon socket head cap bolts: 2-M4×10
7.
Remove the green/yellow ground wire and the green ground wire
connected to X052 and X062 from the cable protection plate.
Cross recessed head screws with captive washer: 2-M4×8
Positions of the ground wire terminals may differ from the photo.
Check which connector the terminal is connected to.
8.
Remove the following connectors.
Connector: X052, X062
9.
Remove the Arm #4 cable bracket and the cable protection sheet.
Hexagon socket head cap bolts: 2-M3
×
6
The Arm #4 cable bracket and cable protection sheet will be used
again. Be careful not to lose them.
Summary of Contents for C12 Series
Page 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C12 series Rev 3 ...
Page 8: ...vi C12 Rev 3 ...
Page 14: ...Table of Contents xii C12 Rev 3 ...
Page 16: ......
Page 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Page 84: ......
Page 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Page 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Page 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...