Maintenance 8. Joint #4
C12 Rev.3
239
10.
Remove the air tube (blue) from the fitting.
11.
Remove the Arm #4 maintenance cover.
For details, refer to
Maintenance: 3 Covers
.
12.
Remove the Arm #4 cable bracket and the cable protection sheet.
Hexagon socket head cap bolts: 2-M3
×
6
The Arm #4 cable bracket and cable protection sheet will be used
again. Be careful not to lose them.
13.
Pull the following parts from the Arm #4 to the Arm #3.
LAN cable
X052 and X062 cables
Ground wire
Air tube (blue)
Protect the connectors with masking tapes.
-
To protect the connector’s clips
-
To avoid adherence of cable grease
14.
Remove the Joint #4 timing belt.
Summary of Contents for C12 Series
Page 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C12 series Rev 3 ...
Page 8: ...vi C12 Rev 3 ...
Page 14: ...Table of Contents xii C12 Rev 3 ...
Page 16: ......
Page 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Page 84: ......
Page 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Page 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Page 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...