Maintenance 16. Calibration
C12 Rev.3
295
EPSON
RC+
4-2 Reset the encoder.
Execute one of the following commands to reset the encoder of the joint you
want to calibrate from the menu-[Tool]-[Command Window].
Joint #1
>Encreset 1
Joint #2
>Encreset 2
Joint #3
>Encreset 3
Joint #4
>Encreset 4
Joint #5
>Encreset 5, 6
Joint #6
>Encreset 6
EPSON
RC+
4-3 Reboot the Controller.
Click EPSON RC+ menu-[Tool]-[Controller]-<Reset Controller>.
EPSON
RC+
4-4 Input the command in the Command window and execute it.
Execute one of the following commands to reset the encoder of the joint you
want to calibrate from the menu-[Tool]-[Command Window].
>calpls 0,0,0,0,0,0
* Manipulator does not move.
EPSON
RC+
4-5 Perform the calibration.
Execute one of the following commands to reset the encoder of the joint you
want to calibrate from the menu-[Tool]-[Command Window].
Joint #1
>calib 1
Joint #2
>calib 2
Joint #3
>calib 3
Joint #4
>calib 4
Joint #5
>calib 5,6
Joint #6
>calib 6
Move the arm to several points to check if the arm moves to the original
positions properly.
Teach points if fine adjustment is necessary.
Summary of Contents for C12 Series
Page 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C12 series Rev 3 ...
Page 8: ...vi C12 Rev 3 ...
Page 14: ...Table of Contents xii C12 Rev 3 ...
Page 16: ......
Page 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Page 84: ......
Page 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Page 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Page 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...