Setup & Operation 3. Environment and Installation
C12 Rev.3
33
Cleanroom-model Manipulator
For the Cleanroom-model, an exhaust system is necessary. For details, refer to
Setup &
Operation: 2.6 Specifications
.
M/C Cable Connection method
Connect the power connector and the signal connector of the M/C cables to the Controller.
Grounding
WARNING
■
Ground resistance must be 100
Ω
or less. Improper ground resistance may
result in fire and/or electric shock.
■
Do not use the ground line for the Manipulator in common with other ground lines
or grounding electrodes for other electric power, motor power, welding devices,
etc. Using the ground line for the Manipulator in common with other ground lines
or grounding electrodes may result in electric shock and/or malfunction of the
robot system.
■
When using metal ducts, metallic conduits, or distributing racks for cable, ground
in accordance with national and local electric equipment technical standards.
Grounding that does not meet the standards may result in electric shock and/or
malfunction of the robot system.
Follow local regulations for grounding. It is recommended that the core size of the
grounding wire be 5.5 mm
2
or more.
Directly connect the ground line to the Manipulator as shown in the figure below.
Detail of A
5.5 mm
2
or more
Bolt hole M5 (for grounding)
Summary of Contents for C12 Series
Page 1: ...Rev 3 EM204R4255F 6 Axis Robots C12 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual C12 series Rev 3 ...
Page 8: ...vi C12 Rev 3 ...
Page 14: ...Table of Contents xii C12 Rev 3 ...
Page 16: ......
Page 30: ...Setup Operation 2 Specifications 16 C12 Rev 3 2 4 Outer Dimensions Unit mm ...
Page 84: ......
Page 155: ...Maintenance 4 Cable Unit C12 Rev 3 141 4 2 Connector Pin Assignment 4 2 1 Signal Cable ...
Page 156: ...Maintenance 4 Cable Unit 142 C12 Rev 3 ...
Page 157: ...Maintenance 4 Cable Unit C12 Rev 3 143 ...
Page 158: ...Maintenance 4 Cable Unit 144 C12 Rev 3 4 2 2 Power Cable ...