Setup & Operation 5. Motion Range
52
C12 Rev.3
5.1.3 Max. Pulse Range of Joint #3
Pulse values in clockwise direction are positive (+) and values in counterclockwise direction
are negative (
-
).
-
61
°
+
202
°
+
13238272 pulse
-
3997696 pulse
Arm #3
0 pulse position
5.1.4 Max. Pulse Range of Joint #4
From the angle of arm end, clockwise pulse values are positive (+) and counterclockwise
pulse values are negative (
-
).
−
5461400 pulse
+5461400 pulse
+
200
°
-
200
°
Arm #4
0 pulse position