86
Chapter3 Handling
Code128
•
If you have disabled the auto convert function, enter a two-digits start code at the beginning of the data. If
you have enabled the auto convert function, the type of start character is automatically determined and you
do not need to specify the type in your application.
∗
An error will occur if you add {A, which sets the type to CODE A, when CODE A has already been selected as the start
character.
∗
An error will occur if you add {B, which sets the type to CODE B, when CODE B has already been selected as the start
character.
∗
An error will occur if you add any one of the following characters when CODE C has already been selected as the start
character.
{S {C {2 {3 {4 {{
•
A special character is expressed by a combination of { and the next character.
Control character
ASCII
HRI character
SHIFT
{S
Not printed
CODE A
{A
Not printed
CODE B
{B
Not printed
CODE C
{C
Not printed
FNC1
{1
Not printed
FNC2
{2
Not printed
FNC3
{3
Not printed
FNC4
{4
Not printed
‘{‘
{{
{ is printed.